SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:gup.ub.gu.se/303216"
 

Search: onr:"swepub:oai:gup.ub.gu.se/303216" > Effect of biofilm f...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Effect of biofilm formation on implant abutments with an anti-bacterial coating: A pre-clinical in vivo study

Almohandes, Ahmed (author)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi,Institute of Odontology
Abrahamsson, Ingemar, 1953 (author)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi, sektion 2,Institute of Odontology, Section 2
Dahlén, Gunnar, 1944 (author)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi, sektion 3,Institute of Odontology, Section 3
show more...
Berglundh, Tord, 1954 (author)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi, sektion 2,Institute of Odontology, Section 2
show less...
 (creator_code:org_t)
2021-03-24
2021
English.
In: Clinical Oral Implants Research. - : Wiley. - 0905-7161 .- 1600-0501. ; 32:6, s. 756-766
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Objectives To analyse the long-term effect of plaque formation on implant abutments with an antibacterial coating and the ensuing host response in peri-implant tissues. Materials and methods Four implants were installed in each mandibular premolar region following tooth extraction in six dogs. Three months later, two test abutments with a titanium-bismuth-gallium (Ti-Bi-Ga) coating and two control titanium abutments were connected to the implants on each side of the mandible. After 2 months, ligatures were placed around the implants in one side of the mandible and plaque formation was allowed until the end of the experiment. The ligatures were removed after 4 weeks. Radiographs and microbiological samples were obtained from each implant site during the plaque formation period. Biopsies were obtained 8 months after abutment connection and prepared for histological analysis. Results The analysis did not reveal any statistically significant differences in bone loss, bacterial growth and size of inflammatory lesions between implant units with and without the Ti-Bi-Ga coating. Implant sites exposed to the short period of ligature-induced breakdown demonstrated more pronounced bone loss and bacterial growth than non-ligature sites. Conclusions It is suggested that a Ti-Bi-Ga coating does not prevent biofilm formation on the implant device and does not influence the ensuing host response in the adjacent peri-implant mucosa.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Keyword

bone loss
dental implant
gallium
histology
inflammation
peri‐
implant mucositis
peri‐
implantitis
Dentistry
Oral Surgery & Medicine
Engineering

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Almohandes, Ahme ...
Abrahamsson, Ing ...
Dahlén, Gunnar, ...
Berglundh, Tord, ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Dentistry
Articles in the publication
Clinical Oral Im ...
By the university
University of Gothenburg

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view