Search: onr:"swepub:oai:gup.ub.gu.se/303726" > Quantification of P...
Fältnamn | Indikatorer | Metadata |
---|---|---|
000 | 03489naa a2200385 4500 | |
001 | oai:gup.ub.gu.se/303726 | |
003 | SwePub | |
008 | 240910s2021 | |||||||||||000 ||eng| | |
024 | 7 | a https://gup.ub.gu.se/publication/3037262 URI |
024 | 7 | a https://doi.org/10.1093/rpd/ncab0172 DOI |
040 | a (SwePub)gu | |
041 | a eng | |
042 | 9 SwePub | |
072 | 7 | a ref2 swepub-contenttype |
072 | 7 | a art2 swepub-publicationtype |
100 | 1 | a Meltzer, Carinu Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology4 aut0 (Swepub:gu)xmeltc |
245 | 1 0 | a Quantification of Pulmonary Pathology in Cystic Fibrosis-Comparison Between Digital Chest Tomosynthesis and Computed Tomography. |
264 | c 2021-03-04 | |
264 | 1 | b Oxford University Press (OUP),c 2021 |
520 | a Digital tomosynthesis (DTS) is currently undergoing validation for potential clinical implications. The aim of this study was to investigate the potential for DTS as a low-dose alternative to computed tomography (CT) in imaging of pulmonary pathology in patients with cystic fibrosis (CF).DTS and CT were performed as part of the routine triannual follow-up in 31 CF patients. Extent of disease was quantified according to modality-specific scoring systems. Statistical analysis included Spearman's rank correlation coefficient (r) and Krippendorff's alpha (α).The median effective dose was 0.14 for DTS and 2.68 for CT. Intermodality correlation was very strong for total score and the subscores regarding bronchiectasis and bronchial wall-thickening (r=0.82-0.91, P<0.01). Interobserver reliability was high for total score, bronchiectasis and mucus plugging (α=0.83-0.93) in DTS.Chest tomosynthesis could be a low-dose alternative to CT in quantitative estimation of structural lung disease in CF. | |
650 | 7 | a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Radiologi och bildbehandling0 (SwePub)302082 hsv//swe |
650 | 7 | a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Radiology, Nuclear Medicine and Medical Imaging0 (SwePub)302082 hsv//eng |
650 | 7 | a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Lungmedicin och allergi0 (SwePub)302192 hsv//swe |
650 | 7 | a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Respiratory Medicine and Allergy0 (SwePub)302192 hsv//eng |
700 | 1 | a Gilljam, M4 aut |
700 | 1 | a Vikgren, J4 aut |
700 | 1 | a Norrlund, R R4 aut |
700 | 1 | a Vult von Steyern, K4 aut |
700 | 1 | a Båth, Magnus,d 1974u Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för medicinsk strålningsvetenskap,Institute of Clinical Sciences, Department of Medical Radiation Sciences4 aut0 (Swepub:gu)xbatma |
700 | 1 | a Johnsson, Åse (Allansdotter),d 1966u Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology4 aut0 (Swepub:gu)xjohna |
710 | 2 | a Göteborgs universitetb Institutionen för kliniska vetenskaper, Avdelningen för radiologi4 org |
773 | 0 | t Radiation protection dosimetryd : Oxford University Press (OUP)g 195:3-4, s. 434-442q 195:3-4<434-442x 1742-3406x 0144-8420 |
856 | 4 | u https://academic.oup.com/rpd/advance-article-pdf/doi/10.1093/rpd/ncab017/36450688/ncab017.pdf |
856 | 4 8 | u https://gup.ub.gu.se/publication/303726 |
856 | 4 8 | u https://doi.org/10.1093/rpd/ncab017 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.
Copy and save the link in order to return to this view