SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:gup.ub.gu.se/315100"
 

Search: onr:"swepub:oai:gup.ub.gu.se/315100" > Comparison of porce...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Comparison of porcelain veneer fracture in implant-supported fixed full-arch prostheses with a framework of either titanium, cobalt-chromium, or zirconia: An in vitro study

Vahnstrom, M. (author)
Hammarström Johansson, Petra, 1967 (author)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi, sektion 2,Institute of Odontology, Section 2
Svanborg, Per, 1978 (author)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi, sektion 2,Institute of Odontology, Section 2
show more...
Franke Stenport, Victoria, 1970 (author)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi, sektion 2,Institute of Odontology, Section 2
show less...
 (creator_code:org_t)
2022-03-21
2022
English.
In: Clinical and Experimental Dental Research. - : Wiley. - 2057-4347. ; 8:2, s. 544-551
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Objectives: The aim of this study was to compare porcelain veneer strength on screw-retained implant-supported fixed full-arch prostheses with a framework of either milled titanium (Ti), cobalt-chromium (CoCr), and yttria-stabilized zirconia (Y-TZP) in an in vitro loading model. Materials and Methods: Fifteen screw-retained maxillary implant-supported fullarch prostheses (FDP), five each of Ti, CoCr, and Y-TZP frameworks with porcelain veneers were included. All FDPs were subjected to thermocycling before loading until fracture of the veneer. The load was applied at the distal fossa of the occlusal area of the pontic replacing 24. Fracture loads were analyzed, and the fracture quality was assessed. Statistical analysis on the fracture load was performed using Kruskal-Wallis test. The statistical significance was set at p < .05. Results: There was no statistical significance found between the groups regarding fracture load. The highest and lowest load was seen within the CoCr FDP, varying between 340 and 1484 N. Different types of fracture appearances were seen. The Y-TZP FDPs had a higher number of fractures locally in the loaded area while CoCr and Ti more often showed cracks in the anterior region, at a distance from the loaded area. Conclusions: Within the limitations of this study, the conclusion was that framework material may affect the fracture behavior of maxillary full-arch bridges; however, there were no differences in veneer fracture strength when frameworks of Ti, CoCr, or Y-TZP were compared.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Keyword

fracture strength
implant-supported prostheses
porcelain veneer
technical complications
dental prostheses
strength
survival
failures
crowns
teeth
rates
fpd
Dentistry
Oral Surgery & Medicine

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Vahnstrom, M.
Hammarström Joha ...
Svanborg, Per, 1 ...
Franke Stenport, ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Dentistry
Articles in the publication
Clinical and Exp ...
By the university
University of Gothenburg

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view