SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:gup.ub.gu.se/320932"
 

Search: onr:"swepub:oai:gup.ub.gu.se/320932" > Implant-Supported S...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Implant-Supported Single Crowns with Titanium or Zirconia Abutments: A Retrospective Up-to-5-year Follow-up Study.

Olander, Julia, 1984 (author)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi, sektion 2,Institute of Odontology, Section 2
Wennerberg, Ann, 1955 (author)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi, sektion 2,Institute of Odontology, Section 2
Franke Stenport, Victoria, 1970 (author)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi, sektion 2,Institute of Odontology, Section 2
 (creator_code:org_t)
Quintessence Publishing, 2022
2022
English.
In: The International journal of prosthodontics. - : Quintessence Publishing. - 1942-4426 .- 0893-2174. ; 35:4, s. 387-395
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • To compare the clinical outcomes of single implants with titanium (Ti) or zirconia (Zr) abutments after up to 5 years in function.This study was a retrospective analysis on single implants with screw-retained abutments (Zr or Ti) covered with porcelain veneer placed between 2011 and 2013 at one referral specialist clinic. Clinical data from patient records were collected from 132 patients and 174 implants. Technical complications such as fractures, chipping, and abutment screw loosening were registered. Radiographs were analyzed comparing both annual bone loss and accumulated bone loss at 5 years. In 57 patients with 85 implants, the values of accumulated bone loss at 5 years were compared to baseline.Technical complications occurred in 16 (9%) of the implants, most often during the first year. The following complications were found: fracture of the abutment (n = 1); loosening of the abutment screws (n = 5); and chipping of the porcelain veneer (n = 11). Ti abutments had more complications than Zr abutments (79%). Of all the implants, 45% had an annual bone loss ranging between 0.05 and 2.15 mm, and 59% had an accumulated bone loss at 5 years ranging between 0.05 and 4.25 mm. Zr abutments had a statistically significantly higher amount of yearly and accumulated bone loss at 5 years.Abutment material affected marginal bone loss. The Zr group displayed statistically more bone loss both yearly and after 5 years compared to the Ti group. Technical complications were not affected by abutment material but were affected by age of the patient.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Keyword

Crowns
Dental Abutments
Dental Materials
Dental Porcelain
Follow-Up Studies
Humans
Retrospective Studies
Titanium
Zirconium

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Olander, Julia, ...
Wennerberg, Ann, ...
Franke Stenport, ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Dentistry
Articles in the publication
The Internationa ...
By the university
University of Gothenburg

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view