Search: onr:"swepub:oai:gup.ub.gu.se/325079" >
Long-term performan...
Long-term performance of implants with moderately rough anodized surface supporting single-tooth restorations: A retrospective analysis with an up to 15-year follow-up
-
- Kowar, Jan, 1972 (author)
- Gothenburg University,Göteborgs universitet,Institutionen för odontologi,Institute of Odontology
-
- Lund, Henrik, 1975 (author)
- Gothenburg University,Göteborgs universitet,Institutionen för odontologi,Institute of Odontology
-
- Franke Stenport, Victoria, 1970 (author)
- Gothenburg University,Göteborgs universitet,Institutionen för odontologi,Institute of Odontology
-
(creator_code:org_t)
- 2023-02-23
- 2023
- English.
-
In: Clinical Oral Implants Research. - : Wiley. - 0905-7161 .- 1600-0501. ; 34:4, s. 367-377
- Related links:
-
https://gup.ub.gu.se...
-
show more...
-
https://doi.org/10.1...
-
show less...
Abstract
Subject headings
Close
- ObjectivesThis retrospective study aimed to evaluate long-term clinical and radiologic performance of anodized surface implants supporting single implant restorations. Materials and MethodsPatients who received at least one anodized surface implant for a single-tooth restoration between 2003 and 2004 in the Branemark clinic (Goteborg, Sweden) were included in the study. The assessed outcomes included implant survival, biological and technical complications, as well as marginal bone levels (MBL) based on radiographs. Baseline data on patient demographics, implant placement, and surgery details were also collected. The cumulative survival rate (CSR) was calculated using the Kaplan-Meier survival analysis. ResultsThe study included 97 patients with 129 implants. Mean patient age at the time of implant placement was 31.7 +/- 16.4 years. All implants were placed in a two-stage approach with delayed loading. The last follow-up visit was on average 13.4 +/- 4.8 years after implant insertion. Three implants failed, yielding the implant-level 15-year CSR of 97.4%. Majority of the implants had no biological (70.5%) nor technical (81.4%) complications. The mean MBL was -1.0 +/- 0.7 mm (n = 101) at prosthetic placement and -1.8 +/- 1.0 mm (n = 80) at the last follow-up, while the mean marginal bone loss (MBL) from prosthetic placement to last follow-up was 0.6 +/- 1.1 mm (n = 65). ConclusionsModerately rough anodized implants have shown favorable long-term outcomessingle-tooth indication, with high survival and a low rate of technical complications. Furthermore, long-term studies are needed to present longitudinal data on peri-implantitis.
Subject headings
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Odontologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Dentistry (hsv//eng)
Keyword
- clinical research
- clinical trials
- imaging
- radiology
- surface
- chemistry
- titanium implants
- oxidized surface
- survival
- Dentistry
- Oral Surgery & Medicine
- Engineering
Publication and Content Type
- ref (subject category)
- art (subject category)
Find in a library
To the university's database