SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:gup.ub.gu.se/49422"
 

Search: onr:"swepub:oai:gup.ub.gu.se/49422" > Inflammatory respon...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Inflammatory response to titanium surfaces with with Potential Bioactive Properties: An In Vitro Study

Göransson, Anna, 1970 (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institutionen för odontologi,Institute of Clinical Sciences,Institute of Odontology
Gretzer, Christina, 1954 (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Johansson, Anna, 1963 (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
show more...
Sul, Young-Taeg, 1960 (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Wennerberg, Ann, 1955 (author)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi,Institute of Odontology
show less...
 (creator_code:org_t)
2006
2006
English.
In: Clinical Implant Dentistry and Related Research. ; 8:4, s. 210-217
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Background: The current hard tissue implants research aims to accelerate bone healing by designing surfaces that are bioactive. However, the role of the inflammatory response to these surfaces is so far incompletely described. Purpose: The aim of the study was to evaluate early inflammatory response in vitro to a potentially bioactive surface—an anodized surface with Mg ions incorporated (anodized/Mg)—and to compare it to a turned, a blasted, and an anodized surface. Materials and Methods: An interferometer was used for topographical characterizations. The disks were incubated with human mononuclear cells. Adherent cells were investigated with respect to number of cells, viability, differentiation, and cytokine production with and without lipopolysaccharide stimulation after 24 and 72 hours. Results: The number of adhered mononuclear cells differed significantly between the different modified surfaces, with the highest number on the anodized surface. However, there were no significant differences in cytokine production and differentiation between the different modified surfaces. The amount of anti-inflammatory mediator interleukin-10 remained over time, while the number of cells and pro-inflammatory cytokine tumor necrosis factor-α decreased. The cells were viable on all surfaces, respectively. Conclusion: The anodized surfaces with and without Mg ions showed an increased cell adherence, however, otherwise an inflammatory response similar to the turned and blasted surfaces. Furthermore, the potentially bioactive anodized/Mg surface showed a similar response to the TiUnite-like anodized surface despite the former having a surface roughness of a smoother character.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Göransson, Anna, ...
Gretzer, Christi ...
Johansson, Anna, ...
Sul, Young-Taeg, ...
Wennerberg, Ann, ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Dentistry
Articles in the publication
By the university
University of Gothenburg

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view