SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:gup.ub.gu.se/50910"
 

Search: onr:"swepub:oai:gup.ub.gu.se/50910" > Slow moderate press...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Slow moderate pressure recruitment maneuver minimizes negative circulatory and lung mechanic side effects: evaluation of recruitment maneuvers using electric impedance tomography.

Odenstedt, Helena, 1968 (author)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för anestesiologi och intensivvård,Institute of Surgical Sciences, Department of Anaesthesiology and Intensive Care
Lindgren, Sophie, 1971 (author)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för anestesiologi och intensivvård,Institute of Surgical Sciences, Department of Anaesthesiology and Intensive Care
Olegård, Cecilia, 1967 (author)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för anestesiologi och intensivvård,Institute of Surgical Sciences, Department of Anaesthesiology and Intensive Care
show more...
Erlandsson, Karin, 1973 (author)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för anestesiologi och intensivvård,Institute of Surgical Sciences, Department of Anaesthesiology and Intensive Care
Lethvall, Sven, 1967 (author)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för anestesiologi och intensivvård,Institute of Surgical Sciences, Department of Anaesthesiology and Intensive Care
Åneman, Anders, 1965 (author)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för anestesiologi och intensivvård,Institute of Surgical Sciences, Department of Anaesthesiology and Intensive Care
Stenqvist, Ola, 1944 (author)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för anestesiologi och intensivvård,Institute of Surgical Sciences, Department of Anaesthesiology and Intensive Care
Lundin, Stefan, 1953 (author)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för anestesiologi och intensivvård,Institute of Surgical Sciences, Department of Anaesthesiology and Intensive Care
show less...
 (creator_code:org_t)
2005-09-22
2005
English.
In: Intensive care medicine. - : Springer Science and Business Media LLC. - 0342-4642 .- 1432-1238. ; 31:12, s. 1706-14
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • OBJECTIVE: To evaluate the efficacy of different lung recruitment maneuvers using electric impedance tomography. DESIGN AND SETTING: Experimental study in animal model of acute lung injury in an animal research laboratory. SUBJECTS: Fourteen pigs with saline lavage induced lung injury. INTERVENTIONS: Lung volume, regional ventilation distribution, gas exchange, and hemodynamics were monitored during three different recruitment procedures: (a) vital capacity maneuver to an inspiratory pressure of 40 cmH2O (ViCM), (b) pressure-controlled recruitment maneuver with peak pressure 40 and PEEP 20 cmH2O, both maneuvers repeated three times for 30 s (PCRM), and (c) a slow recruitment with PEEP elevation to 15 cmH2O with end inspiratory pauses for 7 s twice per minute over 15 min (SLRM). MEASUREMENTS AND RESULTS: Improvement in lung volume, compliance, and gas exchange were similar in all three procedures 15 min after recruitment. Ventilation in dorsal regions of the lungs increased by 60% as a result of increased regional compliance. During PCRM compliance decreased by 50% in the ventral region. Cardiac output decreased by 63+/-4% during ViCM, 44+/-2% during PCRM, and 21+/-3% during SLRM. CONCLUSIONS: In a lavage model of acute lung injury alveolar recruitment can be achieved with a slow lower pressure recruitment maneuver with less circulatory depression and negative lung mechanic side effects than with higher pressure recruitment maneuvers. With electric impedance tomography it was possible to monitor lung volume changes continuously.

Keyword

Analysis of Variance
Animals
Atelectasis
prevention & control
Electric Impedance
Hemodynamic Processes
Lung Compliance
Lung Volume Measurements
instrumentation
Positive-Pressure Respiration
methods
Pulmonary Gas Exchange
Pulmonary Ventilation
Random Allocation
Respiratory Distress Syndrome
Adult
diagnosis
therapy
Swine
Tomography
methods

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view