SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:gup.ub.gu.se/55351"
 

Search: onr:"swepub:oai:gup.ub.gu.se/55351" > Femoral alignment o...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Östgaard, Hans-Christian,1948Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för ortopedi,Institute of Surgical Sciences, Department of Orthopaedics (author)

Femoral alignment of the Charnley stem: a randomized trial comparing the original with the new instrumentation in 123 hips.

  • Article/chapterEnglish2001

Publisher, publication year, extent ...

  • 2009-07-08
  • Medical Journals Sweden AB,2001

Numbers

  • LIBRIS-ID:oai:gup.ub.gu.se/55351
  • https://gup.ub.gu.se/publication/55351URI
  • https://doi.org/10.1080/00016470152846529DOI

Supplementary language notes

  • Language:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • Deficient cement mantles are associated with aseptic loosening of the stem component of total hip replacement. In a former study of 206 Charnley stems, we found high frequencies of stem malalignment, especially on the lateral view, consequently resulting in a high percentage of low cement mantle grading. If the "true" lateral radiographic projection is not used, there is a risk that the frequency of mantle defects is underestimated. A logistic regression analysis showed a high correlation between low cement mantle grading and stem loosening after a mean follow-up of 10 years. The new Charnley instrumentation was introduced in 1994 and we started a randomized trial including 123 prostheses to determine whether the new instrumentation improved the position of the stem in both the AP and lateral planes. Postoperative radiographs revealed a significant change in AP positioning-i.e., from a high percentage of varus with the original method to valgus with the new instrumentation. However, there was no difference on the lateral view, with a persisting high frequency of stems with implant-inner cortex contact resulting in high percentages of low cement-mantle grading in both systems. If this deficiency, in a long-term perspective, is associated with aseptic loosening, as many authors have claimed, the manufacturers should address the problem.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Helger, Lilliane,1957Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för ortopedi,Institute of Surgical Sciences, Department of Orthopaedics (author)
  • Regnér, Hans,1923Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för ortopedi,Institute of Surgical Sciences, Department of Orthopaedics (author)
  • Garellick, Göran,1948Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för ortopedi,Institute of Surgical Sciences, Department of Orthopaedics(Swepub:gu)xgargo (author)
  • Göteborgs universitetInstitutionen för de kirurgiska disciplinerna, Avdelningen för ortopedi (creator_code:org_t)

Related titles

  • In:Acta orthopaedica Scandinavica: Medical Journals Sweden AB72:3, s. 228-320001-6470

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Östgaard, Hans-C ...
Helger, Lilliane ...
Regnér, Hans, 19 ...
Garellick, Göran ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Surgery
Articles in the publication
Acta orthopaedic ...
By the university
University of Gothenburg

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view