SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:gup.ub.gu.se/61353"
 

Search: onr:"swepub:oai:gup.ub.gu.se/61353" > A descriptive study...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

A descriptive study on retrieved non-threaded and threaded implant designs

Bolind, Pia, 1953 (author)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna,Institute of Surgical Sciences
Johansson, Carina B., 1955 (author)
Örebro universitet,Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna,Institute of Surgical Sciences,Hälsovetenskapliga institutionen
Becker, W. (author)
show more...
Langer, L. (author)
Sevetz, E. B., Jr. (author)
Albrektsson, Tomas, 1945 (author)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för biomaterialvetenskap,Institute of Surgical Sciences, Department of Biomaterials
show less...
 (creator_code:org_t)
2005-04-27
2005
English.
In: Clinical oral implants research. - : Wiley. - 0905-7161 .- 1600-0501. ; 16:4, s. 447-55
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • OBJECTIVES: In the light microscope compare the amount of bone saucerization for non-threaded cylindrical and threaded implant designs in retrieved samples from patients. MATERIAL AND METHOD: Consecutively received retrieved oral implants from 117 patients, whereof 85 non-threaded cylindrical and 85 Branemark implants, have been included in the study. For 75 non-threaded cylindrical and 46 Branemark implants was the entire implant length available for calculation. Undecalcified ground sections were investigated in the light microscope with calculation of percentage of implant length coronal to the first bone-implant contact and percentage of bone to implant contact. RESULTS: Mean value for implant length coronal to first bone-implant contact was 65%, standard error of the mean (SEM) 3 (range 0-100%), for non-threaded cylindrical implants and 43%, SEM 6 (range 0-100%) for Branemark implants. Mean values of bone contact along the entire implant length was 23%, SEM 2 (range 0-65%), for the non-threaded cylindrical implants and 33%, SEM 5 (range 0-93%) for the Branemark implants. CONCLUSION: Within the limitations of this retrospective, retrieval study non-threaded cylindrical implants demonstrated a greater bone saucerization when evaluated in the light microscope.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Keyword

Adult
Aged
Alveolar Bone Loss/pathology
Alveolar Process/pathology
Coated Materials
Biocompatible/chemistry
*Dental Implants
*Dental Prosthesis Design
Dental Restoration Failure
Durapatite/chemistry
Female
Humans
Male
Middle Aged
Osseointegration
Prosthesis-Related Infections/pathology
Retrospective Studies
Surface Properties
Titanium/chemistry
Medicine

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view