Forearm bone-anchored amputation prosthesis: a case study on the osseointegration

Palmquist, Anders, 1977 (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
Jarmar, T. (author)
Uppsala universitet,Tillämpad materialvetenskap
Emanuelsson, Lena, 1961 (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
show more...
Brånemark, Rickard, 1960 (author)
Engqvist, Håkan, 1972- (author)
Uppsala universitet,Tillämpad materialvetenskap
Thomsen, Peter, 1953 (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
show less...
 (creator_code:org_t)
2009-07-08
2008
English.
In: Acta Orthopaedica. - : Medical Journals Sweden AB. - 1745-3682 .- 1745-3674. ; 79:1, s. 78-85
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • BACKGROUND AND PURPOSE: Bone-anchored titanium implants have been used for anchorage of amputation prostheses for more than one and a half decades. Histo-logical and ultrastructural analyses were performed on a forearm amputation prosthesis after being in use for more than 11 years. MATERIAL, METHODS AND RESULTS: The implant was retrieved from the ulnar bone after a fatigue fracture of the titanium implant, and was clinically stable at the time of removal. The histological findings showed a large amount of bone within the threads and a high degree of apposition of mineralized bone to the implant surface. Ultrastructural analysis of thin samples prepared by focused ion-beam microscopy revealed an electron-dense layer at the interface and direct apposition of crystalline hydroxyapatite at the implant surface. INTERPRETATION: Our observations in this retrieval study provide a structural correlate to the functional properties and clinical results of amputation prostheses.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Biomaterialvetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Biomaterials Science (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)

Keyword

Aged
*Amputation
Amputation Stumps/pathology/surgery
Artificial Limbs
Biocompatible Materials
Durapatite
Forearm/pathology/*surgery
Humans
Male
*Osseointegration/physiology
*Prostheses and Implants/adverse effects
Prosthesis Failure
Stress
Mechanical
Time Factors
Titanium/adverse effects
TECHNOLOGY

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view