Search: onr:"swepub:oai:gup.ub.gu.se/97499" >
High-resolution com...
-
Vikgren, Jenny,1957Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
(author)
High-resolution computed tomography with 16-row MDCT: A comparison regarding visibility and motion artifacts of dose-modulated thin slices and "step and shoot" images
- Article/chapterEnglish2008
Publisher, publication year, extent ...
-
2008-09-01
-
SAGE Publications,2008
Numbers
-
LIBRIS-ID:oai:gup.ub.gu.se/97499
-
https://gup.ub.gu.se/publication/97499URI
-
https://doi.org/10.1080/02841850802078128DOI
Supplementary language notes
Part of subdatabase
Classification
-
Subject category:ref swepub-contenttype
-
Subject category:art swepub-publicationtype
Notes
-
Background: Dose modulation can be used to reduce the radiation dose in computed tomography (CT) examinations while still obtaining the necessary diagnostic image quality. Multidetector-row computed tomography (MDCT) provides the possibility of simultaneous reconstruction of thin and thick slices from the same raw data. Purpose: To compare thin slices reconstructed from a dose-modulated helical acquisition and conventional high-resolution computed tomography (HRCT) images taken with the “step and shoot” technique in terms of visibility and motion artifacts, in order to investigate the possibility of excluding “step and shoot” acquisition from the HRCT examination. Material and Methods: Twenty patients were examined by a dose-modulated helical acquisition, “MDCT smart mA,” and by a noncontiguous cross-sectional high-resolution 16-row MDCT examination, “MDCT step and shoot.” Images from four anatomical levels, made anonymous regarding identity and technical data, were analyzed in random order by four thoracic radiologists. Results: “MDCT smart mA” was worse than “MDCT step and shoot” in terms of visibility. Concerning motion artifacts, “MDCT smart mA” was better than “MDCT step and shoot.” Conclusion: Thin images reconstructed from a dose-modulated 16-row helical MDCT acquisition (“MDCT smart mA”), as performed in our study, do not provide sufficient image quality regarding visibility compared to the “MDCT step and shoot” technique for the latter technique to be excluded from the HRCT examination.
Subject headings and genre
Added entries (persons, corporate bodies, meetings, titles ...)
-
Johnsson, Åse (Allansdotter),1966Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences(Swepub:gu)xjohna
(author)
-
Flinck, Agneta,1953Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences(Swepub:gu)xfliag
(author)
-
Kheddache, Susanne,1949Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences(Swepub:gu)xkhesu
(author)
-
Milde, Helén,1957Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
(author)
-
Båth, Magnus,1974Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences(Swepub:gu)xbatma
(author)
-
Göteborgs universitetInstitutionen för kliniska vetenskaper
(creator_code:org_t)
Related titles
-
In:Acta Radiologica: SAGE Publications49:7, s. 755-7600284-18511600-0455
Internet link
Find in a library
To the university's database
- By the author/editor
-
Vikgren, Jenny, ...
-
Johnsson, Åse (A ...
-
Flinck, Agneta, ...
-
Kheddache, Susan ...
-
Milde, Helén, 19 ...
-
Båth, Magnus, 19 ...
- About the subject
-
- MEDICAL AND HEALTH SCIENCES
-
MEDICAL AND HEAL ...
-
and Clinical Medicin ...
-
and Radiology Nuclea ...
- Articles in the publication
-
Acta Radiologica
- By the university
-
University of Gothenburg