Search: onr:"swepub:oai:lup.lub.lu.se:030e0066-e3b5-42e6-9f6c-55099ead8b3b" >
Characteristics of ...
Characteristics of heat transfer around an obstacle controlled by the presence of ribs
-
- Ghorbani-Tari, Zahra (author)
- Lund University,Lunds universitet,Värmeöverföring,Institutionen för energivetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Heat Transfer,Department of Energy Sciences,Departments at LTH,Faculty of Engineering, LTH
-
- Wang, Lei (author)
- Lund University,Lunds universitet,Värmeöverföring,Institutionen för energivetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Heat Transfer,Department of Energy Sciences,Departments at LTH,Faculty of Engineering, LTH
-
- Sundén, Bengt (author)
- Lund University,Lunds universitet,Värmeöverföring,Institutionen för energivetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Heat Transfer,Department of Energy Sciences,Departments at LTH,Faculty of Engineering, LTH
-
(creator_code:org_t)
- 2016
- 2016
- English 14 s.
-
In: Heat Transfer Research. - 1064-2285. ; 47:10, s. 893-906
- Related links:
-
http://dx.doi.org/10...
-
show more...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
show less...
Abstract
Subject headings
Close
- Using liquid crystal thermography, experimental studies were carried out to investigate the local heat transfer of an obstacle integrated with a rib. The rib was positioned in the upstream region of the obstacle to disturb the boundary layer of the approaching flow by precipitating the flow separation and reatt achment. The spacing between the rib and the obstacle is of primary importance. The spacing S, which is normalized by the spanwise width of the obstacle, is equal to 1.25d and 0.625d. The effect of the rib height-To-hydraulic diameter ratio e/Dh is also of concern in this study. The e/Dh is between 0.039 or 0.078. The Reynolds number based on the spanwise width of the obstacle ranges between 35,600 and 55,600. It was found that the local heat transfer especially in the upstream region was strongly affected by e/Dh and S/d. In the downstream region, the local heat transfer was more affected by the Reynolds number than the rib height and the spacing.
Subject headings
- TEKNIK OCH TEKNOLOGIER -- Maskinteknik -- Energiteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Mechanical Engineering -- Energy Engineering (hsv//eng)
Keyword
- Obstacle
- Rib Spacing
- Ribs
- Separation
Publication and Content Type
- art (subject category)
- ref (subject category)
Find in a library
To the university's database