SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:06961816-e2ad-432a-98fa-3cdec09d364e"
 

Search: onr:"swepub:oai:lup.lub.lu.se:06961816-e2ad-432a-98fa-3cdec09d364e" > Feasibility and con...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Feasibility and constraints of Bragg peak FLASH proton therapy treatment planning

Lövgren, Nathalie (author)
University of Oxford
Fagerström Kristensen, Ingrid (author)
Lund University,Lunds universitet,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Strålterapi,Sektion I,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,LUCC: Lund University Cancer Centre,Other Strong Research Environments,Radiation therapy,Section I,Department of Clinical Sciences, Lund,Faculty of Medicine,Skåne University Hospital
Petersson, Kristoffer (author)
University of Oxford,Skåne University Hospital
 (creator_code:org_t)
2024
2024
English.
In: Frontiers in Oncology. - 2234-943X. ; 14
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Introduction: FLASH proton therapy (FLASH-PT) requires ultra-high dose rate (≥ 40 Gy/s) protons to be delivered in a short timescale whilst conforming to a patient-specific target. This study investigates the feasibility and constraints of Bragg peak FLASH-PT treatment planning, and compares the in silico results produced to plans for intensity modulated proton therapy (IMPT). Materials and method: Bragg peak FLASH-PT and IMPT treatment plans were generated for bone (n=3), brain (n=3), and lung (n=4) targets using the MIROpt research treatment planning system and the Conformal FLASH library developed by Applications SA from the open-source version of UCLouvain. FLASH-PT beams were simulated using monoenergetic spot-scanned protons traversing through a conformal energy modulator, a range shifter, and an aperture. A dose rate constraint of ≥ 40 Gy/s was included in each FLASH-PT plan optimisation. Results: Space limitations in the FLASH-PT adapted beam nozzle imposed a maximum target width constraint, excluding 4 cases from the study. FLASH-PT plans did not satisfy the imposed target dose constraints (D95% ≥ 95% and D2%≤ 105%) but achieved clinically acceptable doses to organs at risk (OARs). IMPT plans adhered to all target and OAR dose constraints. FLASH-PT plans showed a reduction in both target homogeneity (p < 0.001) and dose conformity (non-significant) compared to IMPT. Conclusion: Without accounting for a sparing effect, IMPT plans were superior in target coverage, dose conformity, target homogeneity, and OAR sparing compared to FLASH-PT. Further research is warranted in treatment planning optimisation and beam delivery for clinical implementation of Bragg peak FLASH-PT.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

Bragg peak
feasibility studies
FLASH radiotherapy
intensity-modulated proton therapy
proton therapy

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Lövgren, Nathali ...
Fagerström Krist ...
Petersson, Krist ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
Frontiers in Onc ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view