SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:0affb5b7-c73b-4287-bdee-a72bc67049f2"
 

Search: onr:"swepub:oai:lup.lub.lu.se:0affb5b7-c73b-4287-bdee-a72bc67049f2" > Optimizing fibrosis...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Optimizing fibrosis detection : a comparison of electroanatomical mapping and late enhancement gadolinium magnetic resonance imaging

Bansmann, P. Martin (author)
Hospital Porz am Rhein
Mohsen, Yazan (author)
Lund University,Lunds universitet,Kardiovaskulär forskning - translationella studier,Forskargrupper vid Lunds universitet,Cardiovascular Research - Translational Studies,Lund University Research Groups,Hospital Porz am Rhein
Horlitz, Marc (author)
Hospital Porz am Rhein
show more...
Stöckigt, Florian (author)
University Hospital Bonn
show less...
 (creator_code:org_t)
English.
In: Journal of Interventional Cardiac Electrophysiology. - 1383-875X.
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Background: Fibrotic atrial cardiomyopathy plays an important role in determining the outcome of ablation in patients with atrial fibrillation (AF). Two main methods are being used for the evaluation of fibrosis: voltage-based high-density (HD) electroanatomical mapping (EAM) and late gadolinium enhancement MRI (LGE-MRI). The comparability between both methods in detecting fibrosis has not been systematically investigated. Methods: LGE-MRIs of the left atrium (LA) were performed in 21 patients. LA-fibrosis was evaluated using a custom-designed software generating a 3D-model of the LA. HD-electroanatomical maps were recorded in each patient. After processing the maps and the MRI models by excluding the mitral valve, pulmonary veins, and the left atrial appendage, the LGE areas were measured and compared to the low voltage areas (LVA) in the HD maps using three different cutoff values of 0.5 mV, 0.7 mV, and 1.0 mV. Results: The analysis revealed significant differences between EAM and LGE-MRI in assessing LA-fibrosis at 0.5-mV (for anterior and posterior walls) and 1.0-mV cutoffs (for anterior and posterior wall and septum). However, no significant differences were found between EAM and LGE-MRI when using a 0.7-mV cutoff for all the investigated areas. Conclusions: A voltage cutoff of 0.7 mV provided the best correlation between EAM and LGE MRI for detecting left atrial fibrosis. It supports the idea that a 0.5-mV cutoff may underestimate fibrosis, as areas with local signal voltages between 0.6 and 0.8 mV could also show LGE on MRI. Further research is needed to determine the ideal voltage cutoff for detecting left atrial fibrosis.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

Atrial cardiomyopathy
Atrial fibrillation
Atrial fibrosis
Substrate

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Bansmann, P. Mar ...
Mohsen, Yazan
Horlitz, Marc
Stöckigt, Floria ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
Journal of Inter ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view