SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:0c17dec7-75e1-4ab2-baf5-a242859f6dfc"
 

Search: onr:"swepub:oai:lup.lub.lu.se:0c17dec7-75e1-4ab2-baf5-a242859f6dfc" > Multiple Rotating I...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Multiple Rotating Integrator Controller for Active Filters

Bojrup, Martin (author)
Karlsson, Per (author)
Lund University,Lunds universitet,Industriell elektroteknik och automation,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Industrial Electrical Engineering and Automation,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Alaküla, Mats (author)
Lund University,Lunds universitet,Industriell elektroteknik och automation,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Industrial Electrical Engineering and Automation,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
show more...
Gertmar, Lars (author)
Lund University,Lunds universitet,Industriell elektroteknik och automation,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Industrial Electrical Engineering and Automation,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
show less...
 (creator_code:org_t)
1999
1999
English.
In: EPE 99 Conference Proceedings.
  • Conference paper (peer-reviewed)
Abstract Subject headings
Close  
  • Abstract in UndeterminedA controller scheme based on multiple rotating integrators (MRI) for an active filter is presented, analysed and evaluated. The inherent performance of integrators in the synchronous reference dq-frame for reduction of steady state errors are used in multiple rotating reference frames in order to compensate harmonics to obtain a steady state error equal to zero. Both measurements and simulations clearly verify the advantageous performance in comparison to presently used active filters. Particularly in experimental verification, the MRI controller structure outperforms the alternative methods due to its low sensitivity to parameter variation and non linear properties of the system. This is particularly important since the superiority of the MRI structure is not fully revealed only by simulation. It is shown that the MRI structure do suppress harmonics to the measurement noise level.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Keyword

Active filters
Converter control
Harmonics
Vector control

Publication and Content Type

kon (subject category)
ref (subject category)

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Bojrup, Martin
Karlsson, Per
Alaküla, Mats
Gertmar, Lars
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Electrical Engin ...
and Other Electrical ...
Articles in the publication
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view