Dissolved oxygen controller based on on-line measurements of ammonium combining feed-forward and feedback

Ingildsen, P (author)
Jeppsson, Ulf (author)
Lund University,Lunds universitet,Industriell elektroteknik och automation,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Industrial Electrical Engineering and Automation,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Olsson, Gustaf (author)
Lund University,Lunds universitet,Industriell elektroteknik och automation,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Industrial Electrical Engineering and Automation,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
 (creator_code:org_t)
2002
2002
English.
In: Water Science and Technology. - 0273-1223. ; 45:4-5, s. 453-460
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • As the largest single energy-consuming component in most biological wastewater treatment systems, control of aeration is of great interest seen from an energy savings point of view. This paper suggests a simple way of using on-line ammonium measurements to control aeration in a pre-denitrification plant by controlling the dissolved oxygen setpoint. The controller works primarily by feed-forward based on an ammonium sensor located at the head of the aerobic process part. Using online in-situ sensor measurements directly from the process have the important advantage over effluent measurements that there is no or very short time delay for information. The controller has been implemented in a full-scale wastewater treatment plant for a period of 35 days, During the experiment two identical activated sludge lines were used. The controller was implemented in one line, while the other line worked as a reference for comparison. The preliminary results indicate that the described control strategy leads to energy savings for the aeration in the region of 5-15%, while maintaining approximately the same effluent quality as in the reference line. Even higher energy savings can probably be achieved by optimising the controller. An automatic procedure for updating the controller parameters based on dynamic effluent ammonium measurement has been tested.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Keyword

pre-denitrification plant
full-scale
control
activated sludge process
aeration
nitrogen removal
nutrient sensors

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Ingildsen, P
Jeppsson, Ulf
Olsson, Gustaf
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Electrical Engin ...
and Other Electrical ...
Articles in the publication
Water Science an ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view