SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:136fe80c-cb2e-4352-8098-6c7d6e7fa619"
 

Search: onr:"swepub:oai:lup.lub.lu.se:136fe80c-cb2e-4352-8098-6c7d6e7fa619" > Transfection of HeL...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Transfection of HeLa-cells with pEGFP plasmid power-assisted by impedance electroporation

Glahder, J (author)
Norrild, B (author)
Persson, Mikael B (author)
show more...
Persson, Bertil R (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
show less...
 (creator_code:org_t)
2005
2005
English.
In: Biotechnology and Bioengineering. - : Wiley. - 1097-0290 .- 0006-3592. ; 92:3, s. 267-276
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Bioimpedance spectrometry was applied to study cell viability and pEGFP plasmid-transfection efficiency in electroporation (EP) of 20,000 HeLa cells with 0.3 mu g DNA in 90 mu l low conductivity 0.32 M sucrose medium of pH 7.5. Monopolar rectangular pulses, of field strength 75 V/mm, and pulse length 0.1 ms were applied in 1-16 repetitions with a 10-sec pause interval between pulses. Surviving cells were stained by crystal violet and counted using a confocal microscope. Transfected cells were fixed with 10% formaldehyde and counted as green spots in a fluorescence microscope. In the present investigation we used the method of bioimpedance spectrometry to analyze the effect of EP on survival and transfection ratio of cells in suspension. DC and low-frequency AC currents preferably pass through the medium due to the high impedance of the cell membrane. At frequencies above 10 kHz the impedance of the cell membrane starts to decrease and the impedance value of the cell suspension approach a lower limit value R-infinity at infinite frequency. Recording of electrical impedance spectra of cells in culture was performed over a frequency range of 10 Hz to 125 kHz, allowing separation of the contribution from extracellular space and that of the cell membranes. A parallel resistance capacitance model of the cell suspension was used to evaluate the response of applying EP pulses. The values of the collective membrane resistance R-M decay exponentially (r(2) = 0.995) with the number of applied pulses. The ratio of the extrapolated value of the intact membrane resistance before pulsing, R-M,(O), and the value R-M,R-N after each pulse makes an index of the effect of electroporation on the cells. The ratio R-M,R-N/R-M,(O) as well as the relative change of the dissipation factor, tan delta, on the "Loss Change Index" (LCI) fits well a dose-response model (r(2) = 0.98) with the number of applied pulses. The changes in the model parameters membrane resistance Delta R-M = [1- R-M,(N)/R-M,o] and loss factor [1- tan delta(O)/tan Omega(N)] correlate well with the transfection ratio and fraction of dead cells. Those parameters were used for power-assisted electroporation in monitoring, controlling, and optimizing the EP procedure.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

electro-pulsation
cell survival
bioimpedance spectrometry
cell membrane
permeabilization
MLS-pulse sequence

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Glahder, J
Norrild, B
Persson, Mikael ...
Persson, Bertil ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
Biotechnology an ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view