Comparison of teaching the basic electrocardiographic concept of frontal plane QRS axis using the classical versus the orderly electrocardiogram limb lead displays

Pahlm, Ulrika (author)
Lund University,Lunds universitet,Klinisk fysiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Physiology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
O'Brien, J E (author)
Pettersson, Jonas (author)
show more...
Pahlm, Olle (author)
Lund University,Lunds universitet,Klinisk fysiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Physiology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
White, Thomas (author)
Maynard, C (author)
Wagner, G S (author)
show less...
 (creator_code:org_t)
1997
1997
English.
In: American Heart Journal. - 1097-6744. ; 134:6, s. 1014-1018
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • This study compares the effectiveness of teaching the calculation of frontal plane QRS axis with the use of the classical versus the orderly electrocardiographic limb lead display. Eighty-three students from two environments were randomized into two groups and were taught to determine frontal plane axis with one of the methods. The accuracy and time to determine the axis were tested on 10 electrocardiograms. In the United States the group using the classical display achieved 4.2 (+/-2.7) correct answers, whereas those using the orderly method achieved 6.8 (+/-3.0) (p = 0.0006). The classical group used 9.2 (+/-2.8) minutes to complete the test, whereas the orderly group needed 7.2 (+/-2.0) minutes (p = 0.015). The results achieved in Sweden were similar. The use of the orderly electrocardiographic limb lead display results in greater diagnostic accuracy in less time than the classical display when determining the frontal plane QRS axis.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view