SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:1599421d-b125-405b-a65f-7b0867d26f81"
 

Search: onr:"swepub:oai:lup.lub.lu.se:1599421d-b125-405b-a65f-7b0867d26f81" > Intraobserver repro...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Intraobserver reproducibility of Doppler measurements of uterine artery blood flow velocity in premenopausal women

Valentin, Lil (author)
Lund University,Lunds universitet,Obstetrisk, gynekologisk och prenatal ultraljudsdiagnostik,Forskargrupper vid Lunds universitet,Obstetric, Gynaecological and Prenatal Ultrasound Research,Lund University Research Groups
Sladkevicius, Povilas (author)
Lund University,Lunds universitet,Obstetrisk, gynekologisk och prenatal ultraljudsdiagnostik,Forskargrupper vid Lunds universitet,Obstetric, Gynaecological and Prenatal Ultrasound Research,Lund University Research Groups
Bland, M. (author)
 (creator_code:org_t)
2002-12-12
2001
English.
In: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 17:5, s. 431-433
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • OBJECTIVE: To determine the intraobserver repeatability of Doppler measurements of uterine artery blood flow velocity and the contribution of various factors to within-subject variance. DESIGN: Seventeen healthy premenopausal women underwent vaginal Doppler ultrasound examination of the uterine artery by the same observer. Three measurements were taken at each of three sites: 1) the currently recommended sampling site; 2) the ascending branch of the uterine artery at a level between the lower and middle third of the corpus uteri; 3) 1.5 cm lateral to the recommended sampling site. Three measurements were taken at each site. For each measurement, three uniform consecutive cardiac cycles were analyzed. Peak systolic velocity, time-averaged maximum velocity, and pulsatility index were calculated. Each Doppler shift spectrum was analyzed twice. Thus, for each women, 18 measurement results per sampling site were obtained. Analysis of variance was used. RESULTS: The effect of sampling site on measurements of peak systolic velocity and time-averaged maximum velocity was non-significant, but pulsatility index values obtained at the distal sampling site were slightly higher than those obtained at the other sites (P = 0.01). Repetition accounted for most of the within-subject variance. Averaging the results of the three repeat measurements yielded increased intraclass correlation coefficients: 0.79-0.89 for peak systolic velocity, 0.80-0.92 for time-averaged maximum velocity and 0.86-0.93 for pulsatility index. CONCLUSION: As the effect of repetition on the results of Doppler measurements of uterine artery blood flow velocity is large, the average of several repeat measurements should be used to enhance measurement reproducibility. However, it is not worth doing more than one analysis of a Doppler shift spectrum, and it is not worth analyzing more than one cardiac cycle per spectrum.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

Doppler ultrasound
Blood flow velocity
Reproducibility
Uterine artery

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Valentin, Lil
Sladkevicius, Po ...
Bland, M.
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
Ultrasound in Ob ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view