SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:16ffa2ce-ae49-4fbf-87cf-c36f3a3a2e20"
 

Search: onr:"swepub:oai:lup.lub.lu.se:16ffa2ce-ae49-4fbf-87cf-c36f3a3a2e20" > A New Method for An...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

A New Method for Analysis of Atrial Activation during Chronic Atrial Fibrillation in Man

Holm, M. (author)
Johansson, Rolf (author)
Lund University,Lunds universitet,Institutionen för reglerteknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Automatic Control,Departments at LTH,Faculty of Engineering, LTH
Olsson, S. Bertil (author)
show more...
Brandt, J. (author)
Lührs, C. (author)
show less...
 (creator_code:org_t)
Institute of Electrical and Electronics Engineers (IEEE), 1996
1996
English.
In: IEEE Transactions on Biomedical Engineering. - : Institute of Electrical and Electronics Engineers (IEEE). - 1558-2531 .- 0018-9294. ; 43:2, s. 198-210
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • To further clarify the mechanisms maintaining chronic atrial fibrillation (CAF), a method identifying preferable activation patterns of the atria during fibrillation, by time averaging of multiple discrete excitation vectors, was developed. Repeated recordings, each of 56 atrial bipolar electrograms simultaneously acquired during 8 s, were made at multiple sites in the right atrial free wall and the left atrial appendage in 16 patients with CAF using a 2.17/spl times/3.54 cm electrode array. The local activation times (LAT's) in each recording were estimated as the median activation time at the respective measurement point. By calculating the time difference between the LAT's at adjacent measurement points in two spatial dimensions, a direction vector was created for each activation wave passing each set of measurement points, a total of 42 sets. By time averaging of the individual direction vectors (typically n=55) at each set of measurement points, preferable activation patterns were determined. Three types of activation patterns were found: 1) inconsistent activation (n=5), 2) consistent activation with preferential propagation directions (n=7) and 3) consistent activation with impulses originating from a localizable site within the recording area (n=4). All activation patterns were reproducible and the two latter patterns were proven significant using statistical tests. It is concluded that this new method is useful in further clarification of the mechanisms involved in the maintenance of atrial fibrillation.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Reglerteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Control Engineering (hsv//eng)

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Holm, M.
Johansson, Rolf
Olsson, S. Berti ...
Brandt, J.
Lührs, C.
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Electrical Engin ...
and Control Engineer ...
Articles in the publication
IEEE Transaction ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view