SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:17ebe3e7-b3f8-4798-a644-8e1d124739e4"
 

Search: onr:"swepub:oai:lup.lub.lu.se:17ebe3e7-b3f8-4798-a644-8e1d124739e4" > Distribution of pre...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Distribution of pressure on the breast in mammography using flexible and rigid compression plates : implications on patient handling

Dustler, Magnus (author)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Radiology Diagnostics, Malmö,Lund University Research Groups,LUCC: Lund University Cancer Centre,Other Strong Research Environments,Skåne University Hospital
Förnvik, Daniel (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Medical Radiation Physics, Malmö,Lund University Research Groups,LUCC: Lund University Cancer Centre,Other Strong Research Environments,Skåne University Hospital
Timberg, Pontus (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups,Skåne University Hospital
show more...
Zackrisson, Sophia (author)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Radiology Diagnostics, Malmö,Lund University Research Groups,LUCC: Lund University Cancer Centre,Other Strong Research Environments,Skåne University Hospital
Muller, Serge (author)
GE Healthcare, France
show less...
 (creator_code:org_t)
2020-12-06
2021
English.
In: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 62:12, s. 1583-1591
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Background: Breast compression in mammography is important but is a source of discomfort and has been linked to screening non-attendance. Reducing compression has little effect on breast thickness, and likely little effect on image quality, due to force being absorbed in the stiff juxta thoracic area instead of in the central breast. Purpose: To investigate whether a flexible compression plate can redistribute force to the central breast and whether this affects perceived pain. Material and Methods: Twenty-eight women recalled from mammography screening were compressed with flexible and rigid plates while retaining force and positioning, 15 in the craniocaudal (CC) view and 13 in the mediolateral oblique (MLO) view. Pressure distribution was continuously measured using pressure sensors. Results: The flexible plate showed greater mean breast pressure in both views: 2.8 versus 2.3 kPa for CC (confidence interval [CI] = 0.2–0.8) and 1.0 versus 0.5 kPa for MLO (CI = 0.2–0.6). The percentage of applied force distributed to the breast was significantly higher with the flexible plate, both on CC (36% vs. 22%, CI = 1–11) and MLO (30% vs. 14%, CI = 4–13). Conclusion: The flexible plate redistributes pressure to the central breast, achieving a better compression, particularly in the MLO view, though much applied force is still applied to the juxta thoracic region.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

breast
breast compression
Mammography
pain

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Dustler, Magnus
Förnvik, Daniel
Timberg, Pontus
Zackrisson, Soph ...
Muller, Serge
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
Acta Radiologica
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view