SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:1a7f4bd0-823c-4009-af4c-17b54a567cb6"
 

Search: onr:"swepub:oai:lup.lub.lu.se:1a7f4bd0-823c-4009-af4c-17b54a567cb6" > Lung mechanics, gas...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Lung mechanics, gas exchange and central circulation during treatment of intra-abdominal hemorrhage with pneumatic anti-shock garment and intra-aortic balloon occlusion. An experimental study in pigs

Blomquist, Sten (author)
Lund University,Lunds universitet,Anestesiologi och intensivvård,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Anesthesiology and Intensive Care,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
Åberg, T (author)
Solem, Jan Otto (author)
Lund University,Lunds universitet,Thoraxkirurgi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Thoracic Surgery,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
show more...
Steen, Stig (author)
Lund University,Lunds universitet,Thoraxkirurgi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Thoracic Surgery,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
show less...
 (creator_code:org_t)
S. Karger AG, 1994
1994
English.
In: European Surgical Research. - : S. Karger AG. - 0014-312X .- 1421-9921. ; 26:4, s. 240-247
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Standardized intra-abdominal hemorrhage was induced in 7 anesthetized pigs. The resulting hypovolemic shock was treated with pneumatic anti-shock garment (PASG) followed by intra-aortic balloon occlusion. The effects of this treatment on circulation, lung mechanics and gas exchange were studied. Hemorrhage was induced by pulling out sutures introduced in the inferior caval vein. We found that the use of PASG partially restored mean arterial blood pressure from 44 +/- 6 to 66 +/- 6 mm Hg. When intraaortic balloon occlusion was added, the arterial pressure returned to basal levels. Cardiac output fell severely due to the hemorrhage from 3.7 +/- 0.2 to 1.3 +/- 0.2 liters/min and could not be restored during the treatment. A severe fall in total lung compliance was recorded after inflation of the PASG from 18.6 +/- 0.9 to 10 +/- 0.7 ml/cm H2O, this was accompanied by a fall in alveolar ventilation. These findings emphasize the severe restriction in lung function that occurred during treatment with PASG. Both parameters returned to near normal values when the PASG was deflated and the intra-aortic balloon was inflated. Pulmonary vascular resistance increased by more than 400% and remained high during the study period. There was no change in arterial PO2, however the fall in mixed venous PO2 caused by hemorrhage was reversed at the end of the treatment. Indirect monitoring of cerebral function by continuous EEG showed a decreased voltage during the hemorrhage, this was reversed by the combined treatment. We conclude that the outlined treatment makes it possible to restore central hemodynamics and preserve cerebral function at least for a short period of time until definite surgical treatment can be performed. However, severe restriction on lung mechanics, especially when PASG was inflated, makes it probable that ventilatory support can be necessary in such cases.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Keyword

Pneumatic anti-shock garment
Intra-aortic balloon
Hemorrhage

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Blomquist, Sten
Åberg, T
Solem, Jan Otto
Steen, Stig
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Surgery
Articles in the publication
European Surgica ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view