Search: onr:"swepub:oai:lup.lub.lu.se:1aaea611-aea9-4553-9a29-66f2c040f707" >
Temperature evaluat...
Temperature evaluation of soft and hard PZT transducers for ultrasonic
-
Johansson, Linda (author)
-
- Evander, Mikael (author)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
Lilliehorn, Tobias (author)
-
show more...
-
- Almqvist, Monica (author)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
- Nilsson, Johan (author)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
- Laurell, Thomas (author)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
Johansson, Stefan (author)
-
Jensen, Klavs F. (editor)
-
Han, Jongyoon (editor)
-
Harrison, D. Jed (editor)
-
Voldman, Joel (editor)
-
show less...
-
(creator_code:org_t)
- 2005
- 2005
- English 3 s.
-
In: Proceedings of µTAS 2005 Conference. ; 2, s. 1428-1430
- Related links:
-
https://lup.lub.lu.s...
Abstract
Subject headings
Close
- This paper reports a comparison of soft and hard piezoceramic transducer materials used for ultrasonic particle trapping in a microfluidic bioanalytical platform. The investigation is made with the objective to obtain high acoustic forces with a minimum of temperature increase. Themperature is a critical parameter for bioassays and most often need to be kept below a certain level to allow handling of e.g. temperature sensitive proteins. The main conclusion in this paper is that it is possible to get efficieint trapping with a temperature increase of only a few degrees using a hard type III transducer material.
Subject headings
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering (hsv//eng)
Keyword
- Acoustic trapping
- temperature
- piezoceramic transducer
- bioanalysis
Publication and Content Type
- kon (subject category)
- ref (subject category)
To the university's database
- By the author/editor
-
Johansson, Linda
-
Evander, Mikael
-
Lilliehorn, Tobi ...
-
Almqvist, Monica
-
Nilsson, Johan
-
Laurell, Thomas
-
show more...
-
Johansson, Stefa ...
-
Jensen, Klavs F.
-
Han, Jongyoon
-
Harrison, D. Jed
-
Voldman, Joel
-
show less...
- About the subject
-
- ENGINEERING AND TECHNOLOGY
-
ENGINEERING AND ...
-
and Medical Engineer ...
- Articles in the publication
- Proceedings of µ ...
- By the university
-
Lund University