SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:2cd57c82-b94d-4474-ad93-35d4bb73b772"
 

Search: onr:"swepub:oai:lup.lub.lu.se:2cd57c82-b94d-4474-ad93-35d4bb73b772" > Mouse S-factors bas...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Mouse S-factors based on monte carlo simulations in the anatomical realistic Moby phantom for internal dosimetry

Larsson, Erik (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Strand, Sven-Erik (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Ljungberg, Michael (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
show more...
Jönsson, Bo-Anders (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
show less...
 (creator_code:org_t)
Mary Ann Liebert Inc, 2007
2007
English.
In: Cancer Biotherapy & Radiopharmaceuticals. - : Mary Ann Liebert Inc. - 1557-8852 .- 1084-9785. ; 22:3, s. 438-442
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Introduction: Biokinetic and dosimetry studies in small animals often precede clinical radionuclide therapies. As in human studies, a reliable evaluation of therapeutic efficacy is essential and must be based on accurate dosimetry, which must be based on a realistic dosimetry model. The aim of this study was to evaluate the differences in the results when using a more anatomic realistic mouse phantom, as compared to previously mathematically described phantoms, based mainly on ellipsoids and cylinders. The difference in results from the two Monte Carlo codes, EGS4 and MCNPX 2.6a, was also evaluated. Methods: An anatomical correct mouse phantom (Moby) was developed by Segars et al. for the evaluation and optimization of the in vivo imaging of mice. The Moby phantom is based on surfaces, which allows for an easy and flexible definition of organ sizes. It includes respiratory movements and a beating heart. It also allows for a redefinition of the location of several internal organs. The execution of he Moby program generates a three-dimensional voxel-based phantom of a specified size, which was modified and used as input for Monte Carlo simulations of absorbed fractions and S-factors. The radiation transport was simulated both with the EGS4 system and the MCNPX 2.6a code. Calculations were done,for the radionuclides F-18, I-124, I-131, In-111, Lu-177, and Y-90. S-factors were calculated using in-house-developed IDL programs and compared with results from previously published models. Results: The comparison of S-factors obtained by the Moby model and mathematical phantoms showed that these, in many cases, were within the same range, whereas for some organs, they were underestimated in the mathematical phantoms. The results were closer to the more anatomically realistic phantom than to the mathematical phantoms, with some exceptions. When investing differences between MCNPX 2.6a and EGS4 using the Moby phantom, results indicated some differences in absorbed fractions for electrons. This reason may be owing to differences in the codes regarding the theory for which electron transport are simulated. Conclusions: It is possible to calculate S-factors that are specific for small animals, such as mice. The Moby phantom is useful as a dosimetry model because it is anatomically realistic, but still very flexible, with 35 accurately segmented regions.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cancer and Oncology (hsv//eng)

Keyword

MCNPX
mouse phantom
small animal dosimetry
Moby
S factors
absorbed fractions
Monte Carlo

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Larsson, Erik
Strand, Sven-Eri ...
Ljungberg, Micha ...
Jönsson, Bo-Ande ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Cancer and Oncol ...
Articles in the publication
Cancer Biotherap ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view