Radiation dose reduction in computed skeletal radiography. Effect on image quality.

Jonsson, A (author)
Herrlin, K (author)
Jonsson, K (author)
show more...
Lundin, Björn (author)
Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Sanfridsson, J (author)
Pettersson, Holger (author)
Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
show less...
 (creator_code:org_t)
1996
1996
English.
In: Acta Radiologica. - 0001-6926. ; 2:37, s. 128-133
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • PURPOSE: To evaluate the effect of radiation dose reduction on image ++quality in computed musculoskeletal radiography and determine optimal exposure range. MATERIAL AND METHODS: In 11 corpses, 1 hand and 1 hip were examined with film-screen radiography, and a series of computed radiographs was obtained using exactly the same technique except for the exposure, which was 100, 50, 25, 12.5, 6.25, and 1.56% of the mAs numbers used for the film-screen images. The computed hip radiographs were processed in 2 different ways, one simulating the film-screen images and one using contrast enhancement. Four radiologists reviewed the images regarding the following parameters: cortical bone, trabecular bone, joint space, and soft tissue, giving each a diagnostic quality rating on a scale from 1 to 5. The median and mean values were found for the pooled results. RESULTS: For the hands, the computed radiographs were ranked inferior to the film-screen images for all parameters except soft tissue, where the computed radiographs scored higher. The computed images with 50 and 25% exposure were ranked equal to the 100% ones. The quality rating slowly declined with lower exposures. For the hips, the 100 and 50% computed radiographs were generally similar to or slightly better than the film-screen images. The decline was somewhat faster than for the hands. The contrast-enhanced hip images scored less than the nonenhanced images at any given exposure for all parameters except soft tissue, where the contrast-enhanced images scored better at all exposures. The difference between nonenhanced and enhanced images became less at the lower exposures. CONCLUSION: Lowering the exposure in computed musculoskeletal radioagrphy below the level of film-screen radiography is feasible, especially in the peripheral skeleton. Contrast enhancement seems to be valuable only in the evaluation of soft-tissue structures.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Jonsson, A
Herrlin, K
Jonsson, K
Lundin, Björn
Sanfridsson, J
Pettersson, Holg ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
Acta Radiologica
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view