SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:4bc1f4aa-786e-4a24-9b41-f7fbdea5a3a6"
 

Search: onr:"swepub:oai:lup.lub.lu.se:4bc1f4aa-786e-4a24-9b41-f7fbdea5a3a6" > Accuracy of duplex ...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Accuracy of duplex sonography before carotid endarterectomy--a comparison with angiography

Hansen, F (author)
Bergqvist, D (author)
Lindblad, Bengt (author)
Lund University,Lunds universitet,Vaskulära sjukdomar - kliniska studier,Forskargrupper vid Lunds universitet,Vascular Diseases - Clinical Research,Lund University Research Groups
show more...
Lindh, Mats (author)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
Mätzsch, Thomas (author)
Lund University,Lunds universitet,Institutionen för kliniska vetenskaper, Malmö,Medicinska fakulteten,Vaskulära sjukdomar - kliniska studier,Forskargrupper vid Lunds universitet,Department of Clinical Sciences, Malmö,Faculty of Medicine,Vascular Diseases - Clinical Research,Lund University Research Groups
Lanne, T (author)
show less...
 (creator_code:org_t)
1996
1996
English.
In: European Journal of Vascular and Endovascular Surgery. - 1532-2165. ; 12:3, s. 331-336
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • OBJECTIVES: The aim of this prospective study was to contribute to the evaluation of the reliability of Duplex sonography (DS) before carotid endarterectomy (CEA). DESIGN: The study was performed prospectively in a university hospital setting. METHODS: Eighty-one consecutive patients aged 49-83 years were examined with DS and carotid angiography (CAG) before CEA. The results of the DS were judged as either confident, or CAG was assessed to be necessary preoperatively. The results from the DS and the CAG were then compared. RESULTS: DS was judged as confident in 148 of the 162 arteries examined. In none of these 148 arteries did CAG change patient management in any way, and the agreement between DS and CAG was good. In the remaining 14 arteries CAG was judged necessary, in 11 arteries because DS assessed the internal carotid artery (ICA) as occluded, which was confirmed by CAG in 10 arteries. In three arteries the reason was poor quality of the DS, however these three arteries were correctly assessed as severely diseased. CONCLUSIONS: This study confirms that DS alone is sufficient in the preoperative evaluation before CEA, provided that CAG is performed whenever DS shows occlusion of the ICA, or when the quality of the DS is poor.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Keyword

Carotid artery
Duplex sonography
Carotid angiography
Carotid artery stenosis
Doppler

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Hansen, F
Bergqvist, D
Lindblad, Bengt
Lindh, Mats
Mätzsch, Thomas
Lanne, T
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Surgery
Articles in the publication
European Journal ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view