SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:5009fafd-af49-409c-8fc8-22de8a97725d"
 

Search: onr:"swepub:oai:lup.lub.lu.se:5009fafd-af49-409c-8fc8-22de8a97725d" > Late aortic arch pe...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Late aortic arch perforation by graft-anchoring stent: complication of endovascular thoracic aneurysm exclusion

Malina, Martin (author)
Lund University,Lunds universitet,Institutionen för kliniska vetenskaper, Malmö,Medicinska fakulteten,Vaskulära sjukdomar - kliniska studier,Forskargrupper vid Lunds universitet,Department of Clinical Sciences, Malmö,Faculty of Medicine,Vascular Diseases - Clinical Research,Lund University Research Groups
Brunkwall, Jan (author)
Ivancev, Krassi (author)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
show more...
Lindblad, Bengt (author)
Lund University,Lunds universitet,Vaskulära sjukdomar - kliniska studier,Forskargrupper vid Lunds universitet,Vascular Diseases - Clinical Research,Lund University Research Groups
Malina, Janne (author)
Nyman, Ulf (author)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
Risberg, Bo (author)
show less...
 (creator_code:org_t)
1998
1998
English.
In: Journal of Endovascular Surgery. - 1074-6218. ; 5:3, s. 274-277
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • PURPOSE: To describe a fatal case of late aortic perforation by an endograft-anchoring stent. METHODS AND RESULTS: A 69-year-old woman presented 2 years after thoracoabdominal aneurysm repair with a 9-cm dilatation of the descending thoracic aorta proximal to the conventional aortic graft. A 38-mm Dacron graft with multiple Gianturco Z-stents sutured inside was placed transluminally across the aortic arch such that part of the uncovered portion of the proximal stent was partially across the left subclavian orifice. Four months later, the patient died from massive hemorrhage. Autopsy showed that the uncovered portion of the proximal stent had perforated the aortic arch. CONCLUSIONS: This case stresses the need for low-profile stent-grafts and smaller, more flexible introducer systems. Anchoring stents must be flexible, less traumatic, and strong enough to create a watertight seal even in tortuous vessels. To avoid aortic arch damage by thoracic stent-grafts, the proximal stent should be fully covered by the fabric.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Keyword

endovascular grafting
complication
Gianturco stent
stent-graft
thoracic aorta

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view