SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:5e61b821-9cfd-42d1-9529-724bf148c5c5"
 

Search: onr:"swepub:oai:lup.lub.lu.se:5e61b821-9cfd-42d1-9529-724bf148c5c5" > Assessment of regio...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Assessment of regional cerebral blood flow by dynamic susceptibility contrast MRI using different deconvolution techniques

Wirestam, Ronnie (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Knutsson, Linda (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,MR Physics,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Lund University Research Groups
Ostergaard, Leif (author)
show more...
Bolling, Max (author)
Aunola, Juha-Petri (author)
Lindgren, Arne (author)
Lund University,Lunds universitet,Neurologi, Lund,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Neurology, Lund,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine
Geijer, Bo (author)
Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Holtås, Stig (author)
Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Ståhlberg, Freddy (author)
Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medicinsk strålningsfysik, Lund,Institutionen för kliniska vetenskaper, Lund,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Medical Radiation Physics, Lund,Department of Clinical Sciences, Lund
show less...
 (creator_code:org_t)
2000
2000
English.
In: Magnetic Resonance in Medicine. - 1522-2594. ; 43:5, s. 691-700
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Regional cerebral blood flow (rCBF) was assessed using dynamic susceptibility-contrast MRI at 1.5 T. A simultaneous dual FLASH pulse sequence and Gd-DTPA-BMA (0.3 mmol/kg b.w.) were used for examination of 43 volunteers, measuring rCBF in frontal white matter (WM) and in gray matter in the thalamus (GM). Arterial input functions (AIFs) were registered 1) in the carotid artery and 2) in an artery within the GM/WM slice. The measured concentration-vs. -time curve was deconvolved with the AIF using both Fourier Transform (FT) and Singular Value Decomposition (SVD). Relative rCBF was given by the height of the deconvolved response curve. For each volunteer, eight different rCBF maps were calculated, representing different combinations of deconvolution techniques, AIFs, and filters. The average GM-WM rCBF ratios ranged from 2.0-2.2, depending on methodology. Absolute rCBF was 68 +/- 28 ml/(min 100 g) in GM and 35 +/- 13 ml/(min 100g) in WM (mean +/- SD, n = 39). GM-WM rCBF ratios obtained using SVD were 6-10% higher than corresponding ratios obtained using FT.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

cerebral blood flow (CBF)
dynamic susceptibility-contrast magnetic resonance imaging (MRI)
nonparametric deconvolution
arterial input function

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view