SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:68a308f5-f66a-484f-8c9c-0c21b1499be5"
 

Search: onr:"swepub:oai:lup.lub.lu.se:68a308f5-f66a-484f-8c9c-0c21b1499be5" > Measuring the local...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Measuring the local pressure amplitude in microchannel acoustophoresis

Barnkob, Rune (author)
Augustsson, Per (author)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Laurell, Thomas (author)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
show more...
Bruus, Henrik (author)
show less...
 (creator_code:org_t)
Royal Society of Chemistry (RSC), 2010
2010
English.
In: Lab on a Chip. - : Royal Society of Chemistry (RSC). - 1473-0189 .- 1473-0197. ; 10:5, s. 563-570
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • A new method is reported on how to measure the local pressure amplitude and the Q factor of ultrasound resonances in microfluidic chips designed for acoustophoresis of particle suspensions. The method relies on tracking individual polystyrene tracer microbeads in straight water-filled silicon/glass microchannels. The system is actuated by a PZT piezo transducer attached beneath the chip and driven by an applied ac voltage near its eigenfrequency of 2 MHz. For a given frequency a number of particle tracks are recorded by a CCD camera and fitted to a theoretical expression for the acoustophoretic motion of the microbeads. From the curve fits we obtain the acoustic energy density, and hence the pressure amplitude as well as the acoustophoretic force. By plotting the obtained energy densities as a function of applied frequency, we obtain Lorentzian line shapes, from which the resonance frequency and the Q factor for each resonance peak are derived. Typical measurements yield acoustic energy densities of the order of 10 J/m(3), pressure amplitudes of 0.2 MPa, and Q factors around 500. The observed half wavelength of the transverse acoustic pressure wave is equal within 2% to the measured width w = 377 mu m of the channel.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering (hsv//eng)

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Barnkob, Rune
Augustsson, Per
Laurell, Thomas
Bruus, Henrik
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Medical Engineer ...
Articles in the publication
Lab on a Chip
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view