A calibration system for soil carbon dioxide efflux measurement chambers: Description and application

Widen, B (author)
Lindroth, Anders (author)
Lund University,Lunds universitet,Institutionen för naturgeografi och ekosystemvetenskap,Naturvetenskapliga fakulteten,Dept of Physical Geography and Ecosystem Science,Faculty of Science
 (creator_code:org_t)
2003
2003
English.
In: Soil Science Society of America Journal. - 0361-5995. ; 67:1, s. 327-334
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Comparisons have revealed large discrepancies among the many methods for measuring soil CO2 efflux indicating the need for an absolute calibration of methods. This study presents a calibration system, constructed to imitate an area of soil, and its application to two different chamber systems for the measurement Of Soil CO2 efflux: one open and one closed dynamic. Air rich in CO2 was allowed to diffuse through a layer of sand on top of a box of known volume. By measuring the decrease in CO2 Concentration inside the box, the exact CO2 efflux could be calculated. The CO2 efflux rates measured by the chambers could then be compared with the efflux rates calculated from the box. The error of the closed-chamber system ranged from an underestimate of 19% to an overestimate of 21%. The errors were most likely caused by a combination of underestimated chamber volume, causing an underestimation Of CO2 efflux, and turbulence within the chamber, which increased the flax by disturbing the boundary layer above the surface. The open-chamber system always overestimated the CO2 efflux. Disturbing the boundary layer alone was believed to cause a 17% increase in efflux. Increasing negative pressure difference caused a mass flow of CO2-rich air into the chamber. At a pressure difference of -0.15 Pa, the error was 11 to 40%, depending on air-filled soil volume. Accordingly, soil-water content, a parameter to which soil CO2 efflux is often related, was found to substantially affect the measurements made by both tested systems. These results point to the need of calibrating systems used for measuring soil CO2 efflux is measured against a known flux, to elucidate the limits and applicability of each system.

Subject headings

NATURVETENSKAP  -- Geovetenskap och miljövetenskap -- Naturgeografi (hsv//swe)
NATURAL SCIENCES  -- Earth and Related Environmental Sciences -- Physical Geography (hsv//eng)

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Widen, B
Lindroth, Anders
About the subject
NATURAL SCIENCES
NATURAL SCIENCES
and Earth and Relate ...
and Physical Geograp ...
Articles in the publication
Soil Science Soc ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view