245 | 1 0 | a Can scatter correction software replace a grid in DR pelvic examinations? |
264 | c 2019-05-21 | |
264 | 1 | b Oxford University Press (OUP),c 2019 |
300 | a 9 s. | |
520 | a The purpose was to examine if scatter correction software could replace a grid while maintaining image quality and reducing radiation dose for pelvic DR examinations. Grid images was produced with 70 kV and 16mAs. Anthropomorphic- and Contrast Detail RADiography (CDRAD) non-grid images were produced with 60 kV, 80 kV and 90 kV combined with five different mAs and scatter correction software. The anthropomorphic images were analyzed by absolute Visual Grading Analysis (VGA). The CDRAD images were analyzed using the CDRAD analysis software. The results showed a total of 54.6% non-grid images were evaluated as unsuitable for diagnostic use by the VGA. The CDRAD grid images showed that the IQF_inv values were significantly different (p = 0.0001) when compared to every group of non-grid images. Hereby, the conclusion stated that the scatter correction software did not compensate for the loss in image quality due to scattered radiation at the exposure levels included in a pelvic examination. | |
650 | 7 | a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Radiologi och bildbehandling0 (SwePub)302082 hsv//swe |
650 | 7 | a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Radiology, Nuclear Medicine and Medical Imaging0 (SwePub)302082 hsv//eng |
653 | a Digital radiography | |
653 | a image quality | |
653 | a pelvic | |
653 | a Radiation dose | |
653 | a Scatter correction software | |
700 | 1 | a Mørup, Svea Deppeu University College Lillebaelt4 aut |
700 | 1 | a Tingberg, Andersu Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine4 aut0 (Swepub:lu)rfa-ati |
700 | 1 | a Outzen, Claus Bjørnu University College Lillebaelt4 aut |
700 | 1 | a Kusk, Kirsten Weberu Hospital of South West Jutland, Esbjerg4 aut |
700 | 1 | a Nielsen, Rita Mølleru Hospital of South West Jutland, Esbjerg4 aut |
700 | 1 | a Midtgård, Marieu Lillebaelt Hospital4 aut |
700 | 1 | a Winther, Martin Brændegaardu Slagelse Hospital4 aut |
700 | 1 | a Waaler, Dagu Norwegian University of Science and Technology4 aut |
700 | 1 | a Kusk, Martin Weberu Hospital of South West Jutland, Esbjerg4 aut |
710 | 2 | a University College Lillebaeltb Medicinsk strålningsfysik, Lund4 org |
773 | 0 | t Radiation Protection Dosimetryd : Oxford University Press (OUP)g 187:1, s. 8-16q 187:1<8-16x 1742-3406x 0144-8420 |
856 | 4 | u http://dx.doi.org/10.1093/rpd/ncz129y FULLTEXT |
856 | 4 8 | u https://lup.lub.lu.se/record/79db9705-dbbc-4bd6-b839-1ed1349eedba |
856 | 4 8 | u https://doi.org/10.1093/rpd/ncz129 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.
Copy and save the link in order to return to this view