SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:7aba7a4c-c982-4255-a56e-8c5c8b71ab95"
 

Search: onr:"swepub:oai:lup.lub.lu.se:7aba7a4c-c982-4255-a56e-8c5c8b71ab95" > Anisotropic micro-s...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Anisotropic micro-sphere-based finite elasticity applied to blood vessel modelling

Alastrue, V (author)
Martinez, M A (author)
Doblare, M (author)
show more...
Menzel, Andreas (author)
Lund University,Lunds universitet,Hållfasthetslära,Institutionen för byggvetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Solid Mechanics,Department of Construction Sciences,Departments at LTH,Faculty of Engineering, LTH
show less...
 (creator_code:org_t)
Elsevier BV, 2009
2009
English.
In: Journal of the Mechanics and Physics of Solids. - : Elsevier BV. - 1873-4782 .- 0022-5096. ; 57:1, s. 178-203
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • A fully three-dimensional anisotropic elastic model for vascular tissue modelling is here presented. The underlying strain energy density function is assumed to additively decouple into volumetric and deviatoric contributions. A straightforward isotropic neo-Hooke-type law is used to model the deviatoric response of the ground substance, whereas a micro-structurally or rather micro-sphere-based approach will be employed to model the contribution and distribution of fibres within the biological tissue of interest. Anisotropy was introduced by means of the use of von Mises orientation distribution functions. Two different micro-mechanical approaches -- a, say phenomenological, exponential ansatz and a worm-like-chain-based formulation -- are applied to the micro-fibres and illustratively compared. The passage from micro-structural contributions to the macroscopic response is obtained by a computational homogenisation scheme, namely numerical integration over the surface of the individual micro-spheres. The algorithmic treatment of this integration is discussed in detail for the anisotropic problem at hand, so that several cubatures of the micro-sphere are tested in order to optimise the accuracy at reasonable computational cost. Moreover, the introduced material parameters are identified from simple tension tests on human coronary arterial tissue for the two micro-mechanical models investigated. Both approaches are able to recapture the experimental data. Based on the identified sets of parameters, we first discuss a homogeneous deformation in simple shear to evaluate the models' response at the micro-structural level. Later on, an artery-like two-layered tube subjected to internal pressure is simulated by making use of a non-linear finite element setting. This enables to obtain the micro- and macroscopic responses in an inhomogeneous deformation problem, namely a blood-vessel-representative boundary value problem. The effect of residual stresses is additionally included in the model by means of a multiplicative decomposition of the deformation gradient tensor which turns out to crucially affect the simulation results.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering (hsv//eng)

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Alastrue, V
Martinez, M A
Doblare, M
Menzel, Andreas
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Mechanical Engin ...
Articles in the publication
Journal of the M ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view