Search: onr:"swepub:oai:lup.lub.lu.se:8d40cf1d-de79-44d9-a347-d1dbd2e9a714" >
Changes in high-fre...
Changes in high-frequency QRS components are more sensitive than ST segment deviation for detecting acute coronary artery occlusion
-
- Pettersson, Jonas (author)
- Lund University,Lunds universitet,Avdelningen för klinisk genetik,Institutionen för laboratoriemedicin,Medicinska fakulteten,Division of Clinical Genetics,Department of Laboratory Medicine,Faculty of Medicine
-
Carro, E. (author)
-
- Edenbrandt, Lars (author)
- Lund University,Lunds universitet,Nuklearmedicin, Malmö,Forskargrupper vid Lunds universitet,Nuclear medicine, Malmö,Lund University Research Groups
-
show more...
-
- Ringborn, Michael (author)
- Lund University,Lunds universitet,Kardiologi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Cardiology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
-
- Sörnmo, Leif (author)
- Lund University,Lunds universitet,Institutionen för elektro- och informationsteknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Electrical and Information Technology,Departments at LTH,Faculty of Engineering, LTH
-
Warren, Stafford G. (author)
-
Wagner, Galen S. (author)
-
show less...
-
(creator_code:org_t)
- 2000
- 2000
- English.
-
In: Journal of the American College of Cardiology. - 0735-1097. ; 36:6, s. 1827-1834
- Related links:
-
http://dx.doi.org/10...
-
show more...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
show less...
Abstract
Subject headings
Close
- OBJECTIVES This study describes changes in high-frequency QRS components (HF-QRS) during percutaneous transluminal coronary angioplasty (PTCA) and compares the ability of these changes in HF-QRS and ST-segment deviation in the standard 12-lead electrocardiogram (ECG) to detect acute coronary artery occlusion. BACKGROUND Previous studies have shown decreased HF-QRS in the frequency range of 150–250 Hz during acute myocardial ischemia. It would be important to know whether the high-frequency analysis could add information to that available from the ST segments in the standard ECG. METHODS The study population consisted of 52 patients undergoing prolonged balloon occlusion during PTCA. Signal-averaged electrocardiograms (SAECG) were recorded prior to and during the balloon inflation. The HF-QRS were determined within a bandwidth of 150–250 Hz in the preinflation and inflation SAECGs. The ST-segment deviation during inflation was determined in the standard frequency range. RESULTS The sensitivity for detecting acute coronary artery occlusion was 88% using the high-frequency method. In 71% of the patients there was ST elevation during inflation. If both ST elevation and depression were considered, the sensitivity was 79%. The sensitivity was significantly higher using the high-frequency method, p < 0.002, compared with the assessment of ST elevation. CONCLUSIONS Acute coronary artery occlusion is detected with higher sensitivity using high-frequency QRS analysis compared with conventional assessment of ST segments. This result suggests that analysis of HF-QRS could provide an adjunctive tool with high sensitivity for detecting acute myocardial ischemia.