Design and dosimetry characteristics of a soft-docking system for intraoperative radiation therapy

Björk, Peter (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Knöös, Tommy (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Nilsson, Per (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
show more...
Larsson, Kurt (author)
show less...
 (creator_code:org_t)
2000
2000
English.
In: International Journal of Radiation Oncology, Biology, Physics. - 0360-3016. ; 47:2, s. 527-533
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • PURPOSE: The design concept and the dosimetric characteristics of an applicator system for intraoperative radiation therapy (IORT) with special emphasis on alignment methods, the effect of a plastic scatterer in the beam, radiation leakage, and misalignment dosimetry, are presented in this paper. MATERIALS AND METHODS: A soft-docking system for a linear accelerator, which enables collimation of electron beams (4-22 MeV) for IORT has been developed. The system includes twenty-one circular polymethylmethacrylate (PMMA) treatment cones of different lengths, diameters and end angles. All in-water measurements are made using p-type silicon diode detectors. RESULTS: The effect of introducing a PMMA scatterer in the therapeutic beam includes increased surface dose values (above 83% for all nominal electron energies and for all cones) and improved dose homogeneity within the therapeutic range. Electrons scattered from the inside wall of the cone result in dose profile horns at depth of dose maximum always lower than 109%. The radiation leakage outside the cone is less than 13%. Large changes in the dose profiles occur if the intraoperative cone is misaligned more than 0.5. CONCLUSION: The alignment procedure of the soft-docking system is easy to handle and the applicator design provides adequate collimation of electron beams for IORT.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

Intraoperative radiation therapy
Electron dosimetry
Applicator system
Radiation leakage
Linear accelerator

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Björk, Peter
Knöös, Tommy
Nilsson, Per
Larsson, Kurt
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
International Jo ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view