SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:983b202c-9d1e-4c4f-aa19-ad6bef3056cf"
 

Search: onr:"swepub:oai:lup.lub.lu.se:983b202c-9d1e-4c4f-aa19-ad6bef3056cf" > Evaluation of optim...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Evaluation of optimally designed planar-concave collimators in single-photon emission tomography

Kimiaei, Shahrok (author)
Ljungberg, Michael (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Larsson, Stig A (author)
 (creator_code:org_t)
Springer Science and Business Media LLC, 1997
1997
English.
In: European Journal Of Nuclear Medicine. - : Springer Science and Business Media LLC. - 1432-105X .- 1619-7070 .- 1619-7089. ; 24:11, s. 1398-1404
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The imaging properties of optimally designed planar-concave (PC) collimators were evaluated by means of Monte Carlo simulations. The evaluation was done with respect to total system spatial resolution and the overall image noise distribution in single-photon emission tomography. The results showed that the non-isotropy with PC collimators, assessed by the ratio of the full-width at half-maximum in the radial and tangential directions, was reduced by about 60% as compared with a conventional parallel-hole collimator for sources located 200 mm away from the centre of rotation. Furthermore, the image noise distribution along the object radius became more uniform when the curved collimator was used. The maximum increase in noise due to use of the curved collimator was about 45% close to the edge of the phantom, where the hole length was about 3 times longer. We also showed with Monte Carlo simulations that the spatial resolution of the lateral cortex when using the curved collimator was significantly improved due to improved radial resolution.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

Spatial resolution
Conventional parallel-hole collimator
Planar-concave collimator
Image noise distribution
Single-photon emission tomography

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Kimiaei, Shahrok
Ljungberg, Micha ...
Larsson, Stig A
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
European Journal ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view