Comparison of tTEM-IP and ERT-IP : cases from mine tailing sites in Sweden

Madsen, L. M. (author)
Aarhus University
Asif, M. R. (author)
Aarhus University
Maurya, P. K. (author)
Aarhus Geoinstruments
show more...
Kühl, A. K. (author)
Aarhus University
Domenzain, D. (author)
Aarhus University
Jensen, C. (author)
Aarhus University
Martin, T. (author)
Lund University,Lunds universitet,Teknisk geologi,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,LTH profilområde: Vatten,LTH profilområden,Engineering Geology,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,LTH Profile Area: Water,LTH Profile areas,Faculty of Engineering, LTH
Bastani, M. (author)
Geological Survey of Sweden
Persson, L. (author)
Geological Survey of Sweden
show less...
 (creator_code:org_t)
2023
2023
English.
In: 29th European Meeting of Environmental and Engineering Geophysics, Held at Near Surface Geoscience Conference and Exhibition 2023, NSG 2023. - 9789462824607
  • Conference paper (peer-reviewed)
Abstract Subject headings
Close  
  • The induced polarization (IP) effect can be studied using both galvanic and inductive methods. Here we study IP and its manifestation in transient electromagnetic (TEM) data from a tTEM system and in time-domain electric resistivity tomography (ERT) data. Since the two methods are sensitive to two different frequency ranges, a direct IP spectrum comparison is not possible. Instead, we assess the IP resolution and compare both resistivity and chargeability inversion results. We show that tTEM data recorded in highly resistive environments with high IP, suffer from fast-decaying transients and sign-changes, which makes it difficult to resolve the true resistivity and IP model due equivalences. A comparison of the maximum phase shifts from two mine tailing sites shows that the chargeability structures gained from the inversion of tTEM data to some degree follow the structures of the chargeability resolved from the ERT data. However, the magnitudes of the resolved phases are generally below 50 mRad for ERT, but up to 500 mRad for tTEM. This indicates that different polarization mechanisms are dominating within the different frequency ranges of the tTEM and ERT methods.

Subject headings

NATURVETENSKAP  -- Geovetenskap och miljövetenskap -- Geofysik (hsv//swe)
NATURAL SCIENCES  -- Earth and Related Environmental Sciences -- Geophysics (hsv//eng)

Publication and Content Type

kon (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view