SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:b9be4413-b801-4712-95cc-e847e0f5ad0b"
 

Search: onr:"swepub:oai:lup.lub.lu.se:b9be4413-b801-4712-95cc-e847e0f5ad0b" > Utformning av utrym...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Utformning av utrymningsplats

Andrée, Kristin (author)
Lund University,Lunds universitet,Avdelningen för Brandteknik,Institutionen för bygg- och miljöteknologi,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Fire Safety Engineering,Department of Building and Environmental Technology,Departments at LTH,Faculty of Engineering, LTH
Jönsson, Axel (author)
Bengtson, Staffan (author)
show more...
Frantzich, Håkan (author)
Lund University,Lunds universitet,Avdelningen för Brandteknik,Institutionen för bygg- och miljöteknologi,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Fire Safety Engineering,Department of Building and Environmental Technology,Departments at LTH,Faculty of Engineering, LTH
show less...
 (creator_code:org_t)
2015
Swedish 133 s.
Series: 1402-3504 ; TVBB-3190
  • Reports (other academic/artistic)
Abstract Subject headings
Close  
  • An investigation regarding the design of a safe refuge area and more specifically the means for communication from the safe refuge areawas performed. Three types of communication techniques were tested using a survey and using experiments in a virtual reality environment; a signal lamp in combination with a push button system, a text display system and finally a voice communication system. According to the Swedish building regulation public buildings and some others shall have safe refuge areas if they are not equipped with a sprinkler system. The safe refuge areas should be located on every floor except on ground floor. Currently there is a lack of guidelines on how the communication between a person staying at the refuge area in the case of a fire and another person inside or outside the building shall be designed. The results indicate that most persons using wheelchairs prefer a voice communication system. The work presents guidelines relevant when designing the safe refuge area. Different views on the design and use of a safe refuge area have been collected using interviews, questionnaires and VR-experiments.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)

Keyword

utrymning
vägledande markeringar
utrymningsplats
brandsäkerhet
funktionsnedsättning
rörelsenedsättning

Publication and Content Type

rap (subject category)
vet (subject category)

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view