SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:ba45bc37-b40c-4aac-b80d-f5606414d188"
 

Search: onr:"swepub:oai:lup.lub.lu.se:ba45bc37-b40c-4aac-b80d-f5606414d188" > Optimizing conventi...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Optimizing conventional cardiac MRI in the rabbit at 0.3 T

Malmgren, N (author)
Laurin, Sven (author)
Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Ståhlberg, Freddy (author)
Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medicinsk strålningsfysik, Lund,Institutionen för kliniska vetenskaper, Lund,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Medical Radiation Physics, Lund,Department of Clinical Sciences, Lund
show more...
Holtås, Stig (author)
Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
show less...
 (creator_code:org_t)
1993
1993
English.
In: Pediatric Radiology. - 1432-1998. ; 23:6, s. 439-441
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The aim of this study was to define the most efficient way of performing cardiac MRI for anatomic information in small experimental animals, using a vertical magnetic field with a strength of 0.3 T (FONAR beta-3000M). This information may be used to improve cardiac MRI in infants and small children, since the size of a rabbit is considered comparable to that of a neonate. Experimental axial cardiac MRI studies were performed in a rabbit under general anesthesia in order to study the effects on image quality of changing various imaging parameters. These are ECG-gating, number of excitations (averages), number of warp levels, echo time (TE) and repetition time (TR). The effects of changing the size of the field of view (FOV), the slice thickness and the phase-encoding direction were also studied. We found that ECG-gating was crucial and that three excitations, TE 16 ms, and 257 vertical phase-encoding warp levels were adequate. Five-millimeter slice thickness and FOV 20 cm were preferred.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Malmgren, N
Laurin, Sven
Ståhlberg, Fredd ...
Holtås, Stig
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
Pediatric Radiol ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view