Results from the first preclinical CT scanner with grating based phase contrast and a rotating gantry
-
- Bech, Martin (author)
- Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Technical University of Munich
-
- Tapfer, Arne (author)
- Technical University of Munich
-
- Velroyen, Astrid (author)
- Technical University of Munich
-
show more...
-
- Yaroshenko, Andre (author)
- Technical University of Munich
-
- Pauwels, Bart (author)
- Bruker microCT
-
- Bruyndonckx, Peter (author)
- Bruker microCT
-
- Liu, Xuan (author)
- Bruker microCT
-
- Sasov, Alexander (author)
- Bruker microCT
-
- Mohr, Jürgen (author)
- Karlsruhe Institute of Technology
-
- Walter, Marco (author)
- microworks GmbH
-
- Pfeiffer, Franz (author)
- Technical University of Munich
-
Momose, Atsushi (editor)
-
Yashiro, Wataru (editor)
-
show less...
-
(creator_code:org_t)
- AIP, 2012
- 2012
- English 7 s.
-
In: International Workshop on X-Ray and Neutron Phase Imaging with Gratings. - : AIP. - 1551-7616 .- 0094-243X. - 9780735410725 ; 1466, s. 130-136
- Related links:
-
http://dx.doi.org/10...
-
show more...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
show less...
Abstract
Subject headings
Close
- After successful demonstrations of soft-tissue phase-contrast imaging with grating interferometers at synchrotron radiation sources and at laboratory based x-ray tubes, a first preclinical CT scanner with grating based phase contrast imaging modality has been constructed. The rotating gantry is equipped with a three-grating interferometer, a 50 watt tungsten anode source and a Hamamatsu flat panel detector. The total length of the interferometer is 45 cm, and the bed of the scanner is optimized for mice, with a scanning diameter of 35 mm. From one single scan both phase-contrast and standard attenuation based tomography can be attained, providing an overall gain in image contrast.
Subject headings
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Keyword
- Preclinical
- Tomography
- X-ray Phase-contrast
Publication and Content Type
- kon (subject category)
- ref (subject category)
Find in a library
To the university's database
- By the author/editor
-
Bech, Martin
-
Tapfer, Arne
-
Velroyen, Astrid
-
Yaroshenko, Andr ...
-
Pauwels, Bart
-
Bruyndonckx, Pet ...
-
show more...
-
Liu, Xuan
-
Sasov, Alexander
-
Mohr, Jürgen
-
Walter, Marco
-
Pfeiffer, Franz
-
Momose, Atsushi
-
Yashiro, Wataru
-
show less...
- About the subject
-
- MEDICAL AND HEALTH SCIENCES
-
MEDICAL AND HEAL ...
-
and Clinical Medicin ...
-
and Radiology Nuclea ...
- Articles in the publication
-
International Wo ...
- By the university
-
Lund University