Search: onr:"swepub:oai:lup.lub.lu.se:bdbc8b80-af57-4ba2-9af6-ff0be9710690" >
Physiological prope...
Physiological properties of the peritoneum in an adult peritoneal dialysis population over a three-year period
-
- Johansson, Ann-Cathrine (author)
- Lund University,Lunds universitet,Institutionen för kliniska vetenskaper, Malmö,Medicinska fakulteten,Department of Clinical Sciences, Malmö,Faculty of Medicine
-
- Haraldsson, Börje, 1957 (author)
- Gothenburg University,Göteborgs universitet,Wallenberglaboratoriet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Wallenberg Laboratory,Institute of Medicine, Department of Molecular and Clinical Medicine
-
(creator_code:org_t)
- 2006
- 2006
- English.
-
In: Peritoneal Dialysis International. - 1718-4304. ; 26:4, s. 482-9
- Related links:
-
http://www.pdiconnec...
-
show more...
-
https://lup.lub.lu.s...
-
https://gup.ub.gu.se...
-
show less...
Abstract
Subject headings
Close
- Objectives: To describe the physiological properties of the peritoneal membrane in adult patients treated with peritoneal dialysis (PD) and to analyze the effects of patient characteristics and time. Design: Observational study. Setting: Department of Nephrology at the Sahlgrenska University Hospital. Method: Peritoneal function was analyzed by the Personal Dialysis Capacity (PDC) test, based on the three-pore theory of capillary transport. The functional PDC variables are absorption, large-pore flow, and the area parameter (A(0)/Delta x), which determines the diffusion of small solutes. The ultrafiltration (UF) coefficient is determined mainly by A(0)/Delta x. Patients: All patients (n = 280) who had at least one PDC test done between September 1990 and August 1999. Results: In 249 patients examined soon after start of PD, area was 19000 (SD 7100) cm(2)/cm/1.73 m(2), large-pore flow 0.112 (SD 0.052) mL/min/1.73 m(2), and the UF coefficient 0.071 (SD 0.032) mL/minute/mmHg/1.73 m(2). Absorption was 1.54 (SD +2.64, -0.97) mL/min/1.73 m(2). Large-pore flow was greater in patients with severe comorbidity than in patients with fewer comorbid conditions. Elderly patients had a lower UF coefficient than did younger patients (p < 0.05). Repeated PDC tests were performed in 208 patients during a mean observation time of 18.4 months. There was a slight increase in the slope of the area-versus-time curve of 54 cm(2)/cm/1.73 m(2) per month (approximately 10% after 3 years, p < 0.01); all other parameters remained constant. Conclusion: Patient characteristics have an impact on peritoneal performance already at the start of dialysis. Peritoneal function can remain essentially stable during medium long-term PD.
Subject headings
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Urologi och njurmedicin (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Urology and Nephrology (hsv//eng)
Keyword
- peritoneal physiology
- Personal Dialysis Capacity (PDC)
Publication and Content Type
- art (subject category)
- ref (subject category)
Find in a library
To the university's database