Influence of the upstream slot geometry on the endwall cooling and phantom cooling of vane suction side surface

Du, Kun (author)
Lund University,Lunds universitet,Värmeöverföring,Institutionen för energivetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Heat Transfer,Department of Energy Sciences,Departments at LTH,Faculty of Engineering, LTH,Xi'an Jiaotong University
Li, Zhigang (author)
Xi'an Jiaotong University
Li, Jun (author)
Xi'an Jiaotong University,Collaborative Innovation Center of Advanced Aero-Engine
show more...
Sunden, Bengt (author)
Lund University,Lunds universitet,Värmeöverföring,Institutionen för energivetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Heat Transfer,Department of Energy Sciences,Departments at LTH,Faculty of Engineering, LTH
show less...
 (creator_code:org_t)
Elsevier BV, 2017
2017
English 13 s.
In: Applied Thermal Engineering. - : Elsevier BV. - 1359-4311. ; 121, s. 688-700
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Modern gas turbines always operate at a high level of inlet temperature. The current inlet temperature in the aircraft and heavy duty gas turbines is higher than the melting point of the guide vane material. Consequently, advanced cooling schemes must be developed to ensure the safe operation of gas turbines. In the current study, numerical simulations were conducted to investigate the influence of the upstream slot geometry on the endwall cooling and phantom cooling of the vane suction side surface. Three-dimensional (3D) Reynolds-averaged Navier–Stokes (RANS) equations combined with the shear stress transport (SST) k-ω turbulence model were solved to conduct the simulations based on the validated turbulence model. The results indicate that the adiabatic cooling effectiveness in the upstream region of the stagnation is significantly increased by introducing the contoured upstream slot. However, the normal upstream slot obtains a relatively high adiabatic cooling effectiveness level in the downstream region of the stagnation. In the present research, the case with normalized amplitude A‾=0.75, initial phase angle φ=45° achieves the largest overall adiabatic cooling effectiveness near the vane leading edge. In contrast, the case with A‾=0.75, φ=30° attains the smallest overall adiabatic cooling effectiveness on the endwall surface. Moreover, the phantom cooling effectiveness on the vane suction side surface is relatively small relative to the adiabatic cooling effectiveness on the endwall. The case with the normal upstream slot achieves the largest phantom cooling effectiveness on the vane suction side surface compared with the contoured upstream slot. Overall, the contoured upstream slot significantly enhances the endwall cooling effectiveness by rearranging the distribution of the coolant mass flowrate at the slot outlet.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)

Keyword

Numerical simulations
Phantom cooling
Upstream slot geometry
Vane endwall

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Du, Kun
Li, Zhigang
Li, Jun
Sunden, Bengt
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Mechanical Engin ...
and Energy Engineeri ...
Articles in the publication
Applied Thermal ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view