SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:cae5b913-415b-416a-aa1b-4a1c4b26d30a"
 

Search: onr:"swepub:oai:lup.lub.lu.se:cae5b913-415b-416a-aa1b-4a1c4b26d30a" > A comparison betwee...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

A comparison between flexible electrogoniometers, inclinometers and three-dimensional video analysis system for recording neck movement

Carnaz, Leticia (author)
Moriguchi, Cristiane S. (author)
de Oliveira, Ana Beatriz (author)
show more...
Santiago, Paulo R. P. (author)
Caurin, Glauco A. P. (author)
Hansson, Gert-Åke (author)
Lund University,Lunds universitet,Avdelningen för arbets- och miljömedicin,Institutionen för laboratoriemedicin,Medicinska fakulteten,Division of Occupational and Environmental Medicine, Lund University,Department of Laboratory Medicine,Faculty of Medicine
Gil Coury, Helenice J. C. (author)
show less...
 (creator_code:org_t)
Elsevier BV, 2013
2013
English.
In: Medical Engineering & Physics. - : Elsevier BV. - 1873-4030 .- 1350-4533. ; 35:11, s. 1629-1637
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • This study compared neck range of movement recording using three different methods goniometers (EGM), inclinometers (INC) and a three-dimensional video analysis system (IMG) in simultaneous and synchronized data collection. Twelve females performed neck flexion-extension, lateral flexion, rotation and circumduction. The differences between EGM, INC, and IMG were calculated sample by sample. For flexion-extension movement, IMG underestimated the amplitude by 13%; moreover, EGM showed a crosstalk of about 20% for lateral flexion and rotation axes. In lateral flexion movement, all systems showed similar amplitude and the inter-system differences were moderate (4-7%). For rotation movement, EGM showed a high crosstalk (13%) for flexion-extension axis. During the circumduction movement, IMG underestimated the amplitude of flexion-extension movements by about 11%, and the inter-system differences were high (about 17%) except for INC-IMG regarding lateral flexion (7%) and EGM-INC regarding flexion-extension (10%). For application in workplace, INC presents good results compared to IMG and EGM though INC cannot record rotation. EGM should be improved in order to reduce its crosstalk errors and allow recording of the full neck range of movement. Due to non-optimal positioning of the cameras for recording flexion-extension, IMG underestimated the amplitude of these movements. (C) 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Arbetsmedicin och miljömedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Occupational Health and Environmental Health (hsv//eng)

Keyword

Neck pain
Movement
Range of motion
Workplace
Goniometer
Kinematics

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view