SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:d1552e2d-54a2-4592-8b3f-a05e1696ab07"
 

Search: onr:"swepub:oai:lup.lub.lu.se:d1552e2d-54a2-4592-8b3f-a05e1696ab07" > A combination of ma...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

A combination of magnetic permeability detection with nanometer-scaled superparamagnetic tracer and its application for one-step detection of human urinary albumin in undiluted urine

Lu, M (author)
Ibraimi, Filiz (author)
Lund University,Lunds universitet,Tillämpad biokemi,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Pure and Applied Biochemistry,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Kriz, D (author)
show more...
Kriz, Kirstin (author)
Lund University,Lunds universitet,Tillämpad biokemi,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Pure and Applied Biochemistry,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
show less...
 (creator_code:org_t)
Elsevier BV, 2006
2006
English.
In: Biosensors & Bioelectronics. - : Elsevier BV. - 1873-4235 .- 0956-5663. ; 21:12, s. 2248-2254
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • A rapid (6.5 min) and simple one-step magnetic immunoassay (MIA) has been developed for analysis of human urinary albumin in near patient settings. Polyclonal rabbit anti-human albumin was used as a capture antibody and monoclonal mouse anti-human albumin as a detection antibody in a two-site immunometric assay requiring no additional washing procedures. The polyclonal anti-human albumin was conjugated to silica microparticles (solid phase) and the monoclonal antibody to dextran-coated nanoscaled superparamagnetic particles (tracer). Quantification of human albumin in undiluted urine was performed by adding 2 mu L urine to a measuring vial containing solid-phase, superpararnagnetic tracer and reaction buffer and then inverting the vial by hand for 20 s. The measuring vial was allowed to stand for 6 min prior to detection, in order for the solid-phase sediment to form at the bottom of the vial. Lastly, the measuring vial was placed into a magnetic permeability detector, which measured the enrichment of superparamagnetic tracer in the sediment due to complex formation with human albumin. Total analysis time was 6.5 min. A linear response was obtained for 0-400 mg/L albumin with a detection limit of 5 mg/L. The total coefficient of variation (CV) was 11% calculated from four consecutive runs on a urine sample containing 11.1 mg/L human albumin during 3 consecutive days. Human urinary albumin analysis was performed on 149 patient samples using the MIA technique and the obtained results showed good correlation with the hospital immunoturbidimetric reference method (y = 1.004x + 4.01, R-2 = 0.978, N= 149) and a commercially available point of care albumin analysis provided by HemoCue Inc. (y = 0.98x + 5.8, R-2 = 0.833, N= 90). (c) 2005 Elsevier B.V. All rights reserved.

Subject headings

NATURVETENSKAP  -- Biologi -- Biokemi och molekylärbiologi (hsv//swe)
NATURAL SCIENCES  -- Biological Sciences -- Biochemistry and Molecular Biology (hsv//eng)

Keyword

tracer
superparamagnetic
anti-human albumin-conjugated
albumin-conjugated silica particles
anti-human
magnetic immunoassay (MIA)
human urinary albumin

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Lu, M
Ibraimi, Filiz
Kriz, D
Kriz, Kirstin
About the subject
NATURAL SCIENCES
NATURAL SCIENCES
and Biological Scien ...
and Biochemistry and ...
Articles in the publication
Biosensors & Bio ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view