SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:d1bf5b63-46e5-4365-a176-6a7663cc2e20"
 

Search: onr:"swepub:oai:lup.lub.lu.se:d1bf5b63-46e5-4365-a176-6a7663cc2e20" > Appearance of coher...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Appearance of coherent artifact signals in femtosecond transient absorption spectroscopy in dependence on detector design

Dietzek, Benjamin (author)
Lund University,Lunds universitet,Kemisk fysik,Enheten för fysikalisk och teoretisk kemi,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Chemical Physics,Physical and theoretical chemistry,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Pascher, Torbjörn (author)
Lund University,Lunds universitet,Kemisk fysik,Enheten för fysikalisk och teoretisk kemi,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Chemical Physics,Physical and theoretical chemistry,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Sundström, Villy (author)
Lund University,Lunds universitet,Kemisk fysik,Enheten för fysikalisk och teoretisk kemi,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Chemical Physics,Physical and theoretical chemistry,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
show more...
Yartsev, Arkady (author)
Lund University,Lunds universitet,Kemisk fysik,Enheten för fysikalisk och teoretisk kemi,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Chemical Physics,Physical and theoretical chemistry,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
show less...
 (creator_code:org_t)
2006-09-18
2007
English.
In: Laser Physics Letters. - : IOP Publishing. - 1612-2011 .- 1612-202X. ; 4:1, s. 38-43
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The appearance of coherent artifact signals in transient absorption spectroscopy employing a spectrally integrated detection system is studied. The influence of the detection design on the shape of the observed signal is detailed and the experimentally very important case, in which the shape of the coherent artifact is strongly influenced by the presence of the sample itself, is considered - leading to the situation that the artifact signal cannot be accounted for by simple comparison of the kinetics obtained for the solvent only. Finally an estimate of the relative contribution of the artifact to the overall transient absorption change is presented facilitating the interpretation of short time transients in the presence of artifact contributions and allowing to estimate the excited state absorption cross-section for a known pump-intensity dependence of the artifact signal.

Subject headings

NATURVETENSKAP  -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)

Keyword

detector design
artifact
coherent
non-linear optics
ultrafast spectroscopy
pulse propagation

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view