SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:d37b8d5d-fdcc-4d02-886e-2d42af360c73"
 

Search: onr:"swepub:oai:lup.lub.lu.se:d37b8d5d-fdcc-4d02-886e-2d42af360c73" > The Reflector: a ne...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

The Reflector: a new method for saving anaesthetic vapours

Perhag, L (author)
Reinstrup, Peter (author)
Lund University,Lunds universitet,Anestesiologi och intensivvård,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Anesthesiology and Intensive Care,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
Thomasson, R (author)
show more...
Werner, Olof (author)
Lund University,Lunds universitet,Anestesiologi och intensivvård,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Anesthesiology and Intensive Care,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
show less...
 (creator_code:org_t)
2000
2000
English.
In: British Journal of Anaesthesia. - 1471-6771. ; 85:3, s. 482-486
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Anaesthesia systems that minimize the use of volatile anaesthetics to reduce cost and pollution are of interest. Closed circuit anaesthesia is the ideal solution, but requires continuous adjustment of fresh gas flow and composition and thus is demanding in routine practice. We describe an alternative system, the Reflector system, which is open in regard to oxygen, nitrogen and N2O, and semiclosed in regard to volatile anaesthetics. The Reflector system is a circle system with a carbon dioxide absorber and an automatic vapour delivery device placed in the inspiratory limb of the circle. A zeolite filter, the Reflector, is placed between the ventilator and the circle. The Reflector functions as a molecular sieve, preventing the volatile anaesthetic from leaving the circle. Isoflurane consumption using the Reflector system in bench tests and an animal study was compared with that of an open system. In bench tests consumption was reduced by 79% and 82%, at a respiratory frequency of 10 and 20 min-1, respectively. The corresponding mean figures from the animal experiment were 65% and 77%.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Anestesi och intensivvård (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Anesthesiology and Intensive Care (hsv//eng)

Keyword

anaesthetic techniques
closed circuit
inhalation
anaesthetics volatile
isoflurane

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Perhag, L
Reinstrup, Peter
Thomasson, R
Werner, Olof
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Anesthesiology a ...
Articles in the publication
British Journal ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view