Search: onr:"swepub:oai:lup.lub.lu.se:d530a642-2c5b-4015-97ef-bc320faf931c" > A preanalytic valid...
Fältnamn | Indikatorer | Metadata |
---|---|---|
000 | 06109naa a2200505 4500 | |
001 | oai:lup.lub.lu.se:d530a642-2c5b-4015-97ef-bc320faf931c | |
003 | SwePub | |
008 | 161228s2016 | |||||||||||000 ||eng| | |
024 | 7 | a https://lup.lub.lu.se/record/d530a642-2c5b-4015-97ef-bc320faf931c2 URI |
024 | 7 | a https://doi.org/10.2967/jnumed.116.1770302 DOI |
040 | a (SwePub)lu | |
041 | a engb eng | |
042 | 9 SwePub | |
072 | 7 | a art2 swepub-publicationtype |
072 | 7 | a ref2 swepub-contenttype |
100 | 1 | a Anand, Aseemu Lund University,Lunds universitet,Urologisk cancerforskning, Malmö,Forskargrupper vid Lunds universitet,Urological cancer, Malmö,Lund University Research Groups4 aut0 (Swepub:lu)med-aa18 |
245 | 1 0 | a A preanalytic validation study of automated bone scan index : Effect on accuracy and reproducibility due to the procedural variabilities in bone scan image acquisition |
264 | c 2016-07-21 | |
264 | 1 | b Society of Nuclear Medicine,c 2016 |
300 | a 7 s. | |
520 | a The effect of the procedural variability in image acquisition on the quantitative assessment of bone scan is unknown. Here, we have developed and performed preanalytical studies to assess the impact of the variability in scanning speed and in vendor-specific γ-camera on reproducibility and accuracy of the automated bone scan index (BSI). Methods: Two separate preanalytical studies were performed: a patient study and a simulation study. In the patient study, to evaluate the effect on BSI reproducibility, repeated bone scans were prospectively obtained from metastatic prostate cancer patients enrolled in 3 groups (Grp). In Grp1, the repeated scan speed and the γ-camera vendor were the same as that of the original scan. In Grp2, the repeated scan was twice the speed of the original scan. In Grp3, the repeated scan used a different γ-camera vendor than that used in the original scan. In the simulation study, to evaluate the effect on BSI accuracy, bone scans of a virtual phantom with predefined skeletal tumor burden (phantom-BSI) were simulated against the range of image counts (0.2, 0.5, 1.0, and 1.5 million) and separately against the resolution settings of the γ-cameras. The automated BSI was measured with a computer-automated platform. Reproducibility was measured as the absolute difference between the repeated BSI values, and accuracy was measured as the absolute difference between the observed BSI and the phantom-BSI values. Descriptive statistics were used to compare the generated data. Results: In the patient study, 75 patients, 25 in each group, were enrolled. The reproducibility of Grp2 (mean ± SD, 0.35 ± 0.59) was observed to be significantly lower than that of Grp1 (mean ± SD, 0.10 ± 0.13; P < 0.0001) and that of Grp3 (mean ± SD, 0.09 ± 0.10; P < 0.0001). However, no significant difference was observed between the reproducibility of Grp3 and Grp1 (P = 0.388). In the simulation study, the accuracy at 0.5 million counts (mean ± SD, 0.57 ± 0.38) and at 0.2 million counts (mean ± SD, 4.67 ± 0.85) was significantly lower than that observed at 1.5 million counts (mean ± SD, 0.20 ± 0.26; P < 0.0001). No significant difference was observed in the accuracy data of the simulation study with vendor-specific γ-cameras (P 5 0.266). Conclusion: In this study, we observed that the automated BSI accuracy and reproducibility were dependent on scanning speed but not on the vendor-specific γ-cameras. Prospective BSI studies should standardize scanning speed of bone scans to obtain image counts at or above 1.5 million. | |
650 | 7 | a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Cancer och onkologi0 (SwePub)302032 hsv//swe |
650 | 7 | a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Cancer and Oncology0 (SwePub)302032 hsv//eng |
650 | 7 | a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Radiologi och bildbehandling0 (SwePub)302082 hsv//swe |
650 | 7 | a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Radiology, Nuclear Medicine and Medical Imaging0 (SwePub)302082 hsv//eng |
653 | a Bone scan | |
653 | a Bone scan index | |
653 | a Imaging biomarker | |
653 | a Metastatic prostate cancer | |
653 | a Pre-analytical validation | |
700 | 1 | a Morris, Michael J.u Memorial Sloan-Kettering Cancer Center,Cornell University4 aut |
700 | 1 | a Kaboteh, Rezau Sahlgrenska University Hospital4 aut |
700 | 1 | a Reza Felix, Marianau Lund University,Lunds universitet,Nuklearmedicin, Malmö,Forskargrupper vid Lunds universitet,Nuclear medicine, Malmö,Lund University Research Groups,Skåne University Hospital4 aut0 (Swepub:lu)med-mre |
700 | 1 | a Trägårdh, Elinu Lund University,Lunds universitet,Klinisk fysiologi och nuklearmedicin, Malmö,Forskargrupper vid Lunds universitet,Clinical Physiology and Nuclear Medicine, Malmö,Lund University Research Groups4 aut0 (Swepub:lu)klin-etr |
700 | 1 | a Matsunaga, Naofumiu Yamaguchi University4 aut |
700 | 1 | a Edenbrandt, Larsu Lund University,Lunds universitet,Nuklearmedicin, Malmö,Forskargrupper vid Lunds universitet,Nuclear medicine, Malmö,Lund University Research Groups,Sahlgrenska University Hospital4 aut0 (Swepub:lu)klfy-led |
700 | 1 | a Bjartell, Andersu Lund University,Lunds universitet,Urologisk cancerforskning, Malmö,Forskargrupper vid Lunds universitet,Urologi,Urological cancer, Malmö,Lund University Research Groups,Urology4 aut0 (Swepub:lu)kir-abj |
700 | 1 | a Larson, Steven M.u Cornell University,Memorial Sloan-Kettering Cancer Center4 aut |
700 | 1 | a Minarik, Davidu Skåne University Hospital4 aut0 (Swepub:lu)radf-dmi |
710 | 2 | a Urologisk cancerforskning, Malmöb Forskargrupper vid Lunds universitet4 org |
773 | 0 | t Journal of Nuclear Medicined : Society of Nuclear Medicineg 57:12, s. 1865-1871q 57:12<1865-1871x 0161-5505x 2159-662X |
856 | 4 | u http://dx.doi.org/10.2967/jnumed.116.177030y FULLTEXT |
856 | 4 | u http://jnm.snmjournals.org/content/57/12/1865.full.pdf |
856 | 4 8 | u https://lup.lub.lu.se/record/d530a642-2c5b-4015-97ef-bc320faf931c |
856 | 4 8 | u https://doi.org/10.2967/jnumed.116.177030 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.
Copy and save the link in order to return to this view