Search: onr:"swepub:oai:lup.lub.lu.se:d6248187-1c0a-4b6b-a7f4-672239eea185" >
Reduction of RV pac...
Reduction of RV pacing by continuous optimization of the AV interval
-
Milasinovic, G (author)
-
Sperzel, J (author)
-
Smith, TW (author)
-
show more...
-
Mead, H (author)
-
- Brandt, Johan (author)
- Lund University,Lunds universitet,Thoraxkirurgi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Thoracic Surgery,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
-
Haisty, WK (author)
-
Bailey, JR (author)
-
Roelke, M (author)
-
Simonson, J (author)
-
Gerritse, B (author)
-
Englund, J (author)
-
Compton, SJ (author)
-
show less...
-
(creator_code:org_t)
- Wiley, 2006
- 2006
- English.
-
In: PACE. - : Wiley. - 1540-8159. ; 29:4, s. 406-412
- Related links:
-
http://dx.doi.org/10...
-
show more...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
show less...
Abstract
Subject headings
Close
- Background: In patients requiring permanent pacing, preservation of intrinsic ventricular activation is preferred whenever possible. The Search AV+ (SAV+) algorithm in Medtronic EnPulse(TM) dual-chamber pacemakers can increase atrioventricular (AV) intervals to 320 ms in patients with intact or intermittent AV conduction. This prospective, multicenter study compared the percentage of ventricular pacing with and without AV interval extension. Methods: Among 197 patients enrolled in the study, the percentage of ventricular-paced beats was evaluated via device diagnostics at the 1-month follow-up. Patient cohorts were defined by clinician assessment of conduction via a 1:1 AV conduction test at the 2-week follow-up. The observed percentage of ventricular pacing with SAV + ON and the predicted percentage of ventricular pacing with SAV + OFF were determined from the SAV + histogram data for the period between the 2-week and 1-month follow-up visits. Results: Of 197 patients, 110 (55.8%) had intact 1:1 AV conduction, of which 109 had 1-month data. SAV + remained ON in 991109 patients; 10 patients had intrinsic A-V conduction intervals beyond SAV + nominal and therefore SAV + disabled. The mean percentage of ventricular pacing in the 109 patients was SAV+ ON = 23.1% (median 3.7%) versus SAV + OFF = 97.2% (median 99.7%). In 87 patients without 1:1 AV conduction, SAV + was programmed OFF in 6, automatically disabled in 52, and remained ON in 29. In 8 of these patients, 80-100% reduction in ventricular pacing was observed with SAV + ON. Conclusion: The Search AV+ algorithm in the EnPulse pacemaker effectively promotes intrinsic ventricular activation and substantially reduces unnecessary ventricular pacing.
Subject headings
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kardiologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
Keyword
- unnecessary ventricular pacing
- intrinsic ventricular activation
- search AV
- dual-chamber pacing
Publication and Content Type
- art (subject category)
- ref (subject category)
Find in a library
-
PACE
(Search for host publication in LIBRIS)
To the university's database
- By the author/editor
-
Milasinovic, G
-
Sperzel, J
-
Smith, TW
-
Mead, H
-
Brandt, Johan
-
Haisty, WK
-
show more...
-
Bailey, JR
-
Roelke, M
-
Simonson, J
-
Gerritse, B
-
Englund, J
-
Compton, SJ
-
show less...
- About the subject
-
- MEDICAL AND HEALTH SCIENCES
-
MEDICAL AND HEAL ...
-
and Clinical Medicin ...
-
and Cardiac and Card ...
- Articles in the publication
-
PACE
-
Pacing and Clini ...
- By the university
-
Lund University