SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:dacbea45-23e3-4603-831a-4840f6e5e2db"
 

Search: onr:"swepub:oai:lup.lub.lu.se:dacbea45-23e3-4603-831a-4840f6e5e2db" > Estimation of Respi...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Estimation of Respiratory Information from the Built-In Pressure Sensors of a Dialysis Machine

Sandberg, Frida (author)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Holmer, Mattias (author)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Olde, Bo (author)
show more...
Solem, Kristian (author)
Gambro AB
Murray, Alan (editor)
show less...
 (creator_code:org_t)
2014
2014
English 4 s.
In: [Host publication title missing]. - 0276-6574. ; 41, s. 853-856
  • Conference paper (peer-reviewed)
Abstract Subject headings
Close  
  • The purpose of the present study is to determine the feasibility of estimating respiratory information from the built-in pressure sensors of a dialysis machine. The study database consists of simultaneous recordings of pressure signals and capnographic signals from 6 patients during 7 hemodialysis treatment sessions. Respiration rates were estimated using respiratory induced variations in the beat- to-beat interval series of the cardiac component of the pressure signal and respiratory induced baseline varia- tions in the pressure signal, respectively. The estimated respiration rates were compared to a reference respira- tion rate determined from the capnograhpic signal. The root-mean-square error of the estimated respiration rate from the baseline variations of the pressure signal was 2.10 breaths/min; the corresponding error of the estimated res- piration rate from the beat-to-beat interval series of the cardiac component was 4.95 breaths/min. The results sug- gest that it is possible to estimate respiratory information from the pressure sensors.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering (hsv//eng)

Publication and Content Type

kon (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Sandberg, Frida
Holmer, Mattias
Olde, Bo
Solem, Kristian
Murray, Alan
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Medical Engineer ...
Articles in the publication
[Host publicatio ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view