Search: onr:"swepub:oai:lup.lub.lu.se:ddb5237f-b93f-41c8-8bce-61a81d5f5461" >
Computer-aided diag...
Computer-aided diagnosis system outperforms scoring analysis in myocardial perfusion imaging
-
Johansson, Lena (author)
-
- Edenbrandt, Lars (author)
- Lund University,Lunds universitet,Institutionen för translationell medicin,Medicinska fakulteten,Department of Translational Medicine,Faculty of Medicine
-
Nakajima, Kenichi (author)
-
show more...
-
Lomsky, Milan (author)
-
Svensson, Sven-Eric (author)
-
- Trägårdh, Elin (author)
- Lund University,Lunds universitet,Klinisk fysiologi och nuklearmedicin, Malmö,Forskargrupper vid Lunds universitet,Clinical Physiology and Nuclear Medicine, Malmö,Lund University Research Groups
-
show less...
-
(creator_code:org_t)
- 2014-01-18
- 2014
- English.
-
In: Journal of Nuclear Cardiology. - : Springer Science and Business Media LLC. - 1532-6551 .- 1071-3581. ; 21:3, s. 416-423
- Related links:
-
http://dx.doi.org/10...
-
show more...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
show less...
Abstract
Subject headings
Close
- The aim of this myocardial perfusion imaging (MPI) study was to compare the diagnostic performance of two computer-aided diagnosis (CAD) systems, EXINI Heart(TM) (EXINI), and PERFEXTM (PERFEX) Emory Cardiac Toolbox (ECT), and the summed stress score (SSS) values from both software packages. We studied 1,052 consecutive patients who underwent 2-day stress/rest Tc-99m-sestamibi MPI studies. The reference standard classifications for the MPI studies were obtained from three experienced physicians who separately classified all cases regarding the presence or absence of ischemia and/or infarction. Automatic processing was carried out using EXINI and PERFEX to obtain CAD results and SSS values based on the 17-segment model. The three experts' classifications showed ischemia in 257 patients and abnormal studies, i.e., either ischemia or infarction or both, in 318 patients. Accuracy was significantly higher in EXINI than in PERFEX, regarding both the detection of ischemia (87.4 vs 77.6%; P < 0.0001) and the detection of abnormal studies (91.6 vs 67.9%; P < 0.0001). EXINI's CAD system showed a higher specificity than its SSS values (86.8 vs 73.6%; P < 0.0001) at the same level of sensitivity. EXINI demonstrated greater diagnostic accuracy for detection of ischemia and abnormal studies than did PERFEX. EXINI CAD also outperformed its SSS analysis.
Subject headings
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Keyword
- Ischemic heart disease
- myocardial perfusion imaging
- SPECT
- automatic
- quantification
- software
Publication and Content Type
- art (subject category)
- ref (subject category)
Find in a library
To the university's database