SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:e39cec33-6785-4da6-809a-fcdbc3f3df0d"
 

Search: onr:"swepub:oai:lup.lub.lu.se:e39cec33-6785-4da6-809a-fcdbc3f3df0d" > Dual-signal analysi...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Dual-signal analysis eliminates requirement for milk sample pretreatment.

Chen, Ying (author)
Lund University,Lunds universitet,Tillämpad biokemi,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Pure and Applied Biochemistry,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Andersson, Anneli (author)
Mecklenburg, Michael (author)
show more...
Xie, Bin (author)
Lund University,Lunds universitet,Tillämpad biokemi,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Pure and Applied Biochemistry,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Zhou, Yikai (author)
show less...
 (creator_code:org_t)
Elsevier BV, 2011
2011
English.
In: Biosensors & Bioelectronics. - : Elsevier BV. - 1873-4235 .- 0956-5663. ; 29:1, s. 115-118
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Detection of analytes in complex biological samples, such as milk and blood, normally requires sample pretreatment. These pretreatment regimes reduce assay throughput and increase testing costs. Technologies that make it possible to eliminate sample pretreatment are of great industrial interest. Here we report the development of a dual-signal flow injected analysis device which eliminates the need for sample pretreatment. The device employs thermal traducers to measure the signal from an enzyme and a reference column. This makes it possible to independently monitor and correct for non-specifically generated heat, thereby eliminating the need for sample pretreatment. The ability of the dual-signal device to determine urea and lactate in milk samples without any prior treatment was evaluated. The spiked milk samples, the urea assay had a linear range from 0.1 to 50mM (R=0.996), and the lactate assay had a linear range from 0.025 to 5.0mM (R=0.9998). The linear regression values for urea and lactate for 0.5%, 1.5% and 3.0% fat milk were at least 0.990. The dual-signal design improves assay reproducibility, accuracy and sensitivity. Addition benefits are shorter assay times and lowers costs, as well as reducing equipment and training requirements. The potential application of the technology for multi-analyte analysis in point of care and decentralized diagnostic testing in healthcare, agriculture and environmental areas is discussed.

Subject headings

NATURVETENSKAP  -- Biologi -- Biokemi och molekylärbiologi (hsv//swe)
NATURAL SCIENCES  -- Biological Sciences -- Biochemistry and Molecular Biology (hsv//eng)

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Chen, Ying
Andersson, Annel ...
Mecklenburg, Mic ...
Xie, Bin
Zhou, Yikai
About the subject
NATURAL SCIENCES
NATURAL SCIENCES
and Biological Scien ...
and Biochemistry and ...
Articles in the publication
Biosensors & Bio ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view